background image

Lutron Electronics Co., Inc.

7200 Suter Road

Coopersburg, PA  18036-1299, U.S.A.

Made and printed in the U.S.A.  2/08  P/N 044-109  Rev. A

Warranty: For Warranty information, please see the Warranty enclosed with the 

product, or visit www.lutron.com/resiinfo.

These products may be covered under one or more of the following U.S. pat-

ents: 5,838,226; 5,848,054; 5,905,442; 6,687,487; 6,803,728 and correspond-

ing foreign patents. U.S. and foreign patents pending. 

Lutron,  AuroRa  and  the  sunburst  logo  are  registered  trademarks  of  Lutron 

Electronics Co., Inc.

© 2007 Lutron Electronics Co., Inc.

1

ARMC-5T

Troubleshooting

Symptom

The Tabletop Master Control is not  
communicating with the system.

 
Cannot activate Tabletop Master Control 

Possible Cause

Tabletop Master Control has not been activated in the system.
•  Activate Tabletop Master Control in the system, following the instructions 

on page 3.

A maximum of one (1) Tabletop Master Control can be activated in the  
system.
•  Call the Lutron Technical Support Center at +1.800.523.9466 for  

assistance.

 
Operating the Tabletop Master Control

Installation Instructions for 
Replacement Tabletop Master Control

Read all instructions completely before installation.

AuroRA

®

 Tabletop Master Control

ARMC-5T

DC Adapter: 9 V 

  300 mA

DC Adapter for Tabletop Master Control

T120-9DC-3-WH 

Input 120 V

  60 Hz  6.5 W; Output 9 V

  300 mA

Overview

The ARMC-5T Tabletop Master Control is for use 
with 

AuroRa

 systems in conjunction with the Central 

Antenna (AR-CA-WH) or Security Interface (AR-SI-
WH), and allows the wireless activation of 

AuroRa

 

Dimmers / Switches.

Important Notes

Environment:

 Ambient operating temperature: 32 °F 

to 104 °F (0 °C to 40 °C). 0% to 90% humidity, non-
condensing. Indoor use only.

Finish:

 Do not paint the Tabletop Master Control.

Cleaning:

 To clean, wipe with a clean damp cloth. 

Do noT use any chemical cleaning solutions.

Power: 

Use only the adapter provided by Lutron  

(T120-9DC-3-WH) with your Tabletop Master Control. 
Using an adapter not rated at the following specifica-
tions could damage the control and possibly overheat 
the adapter. 
• Input: 120 V

 

 60 Hz 

• output: 9 V   300 mA  nEC

®

 Class 2; IEC PELV

Radio Frequency Range:

 The Tabletop Master 

Control should be located within 30 feet (10 m) of 
the Central Antenna or Security Interface. The per-
formance of the Tabletop Master Control is highly 
dependent upon a variety of  
complex factors such as: 
 

• Distance 

 

• Construction of walls 

 

• Electrical equipment nearby

System Control:

 Before the Tabletop Master Control 

may be used to control lights in the 

AuroRa

 system, it 

must be activated.

5

4

3

2

1

All on - Turns 
all dimmers on 
to full

Buttons - Turn individual 
dimmers on to local  
dimmer slider level

All off - Turns 
all dimmers off

FCC Information
Note:

 This equipment has been tested and found to comply with 

the limits for a Class B digital device, pursuant to Part 15 of the 

FCC rules. Operation is subject to the following: (1) This device 

may not cause harmful interference, and (2) this device must 

accept any interference received, including interference that may 

cause undesired operation.

5

4

3

2

1

T120-9DC-3-WH

Reviews: