A-8
CDD3000-HF Operation Manual
A.2
Ambient
conditions
Characteristic
drive controller
Temperature
range
in operation
-10 ...45 °C (BG1 ... BG5)
with power reduction to 55 °C
in storage
-25 ... +55 °C
in transit
-25 ... +70 °C
Relative air humidity
15 ... 85 %, condensation not permitted
Mechanical
strength to
IEC 68-2-6
Vibration
0.075 mm in frequency range 10 ... 57 Hz
1 g in frequency range 57 ... 150 Hz
Protection
Device
IP20 (NEMA 1)
Cooling
method
Cold plate: IP20
Push-through heat sink: IP54 (3 ...15 kW)
Touch protection
VBG 4
Mounting height
up to 1000 m above MSL, above 1000 m above MSL
with power reduction 1% per 100 m, max. 2000 m
above MSL
max. holding brake current 2 A to T
U
= 45°C,
derating 50 mA/°C to T
Umax
= 55°C
Voltage stress of the
motor winding
typical
slew rate 3 - 6 kV/
µ
s