Installation and Operating Manual  

Smart Comfort 5/SC-FT 

- Please forward to the user -  

Contents: 

About this manual, Safety instructions, Disposal 

 

 

 2 

Technical data, Shipping unit and dimensions  

 

 

 3 

Installation 

 

 

 

 

 

 

 5 

Electrical connection 

 

 

 

 

 

 7 

Specify the connected device type   

 

 

 

12 

Programming mode 

 

 

 

 

 

13 

DIP-switch settings 

 

 

 

 

 

14 

Operating element - setting options   

 

 

 

15 

Symbol descriptions 

 

 

 

 

 

16 

Factory settings   

 

 

 

 

 

18 

Filter replacement and filter cleaning  

 

 

 

19

 

Page:

 

 

Summary of Contents for Smart Comfort 5/SC-FT

Page 1: ...y instructions Disposal 2 Technical data Shipping unit and dimensions 3 Installation 5 Electrical connection 7 Specify the connected device type 12 Programming mode 13 DIP switch settings 14 Operating...

Page 2: ...he supply voltage This symbol warns you against risks of injury This symbol warns you against risks of injury from electricity Attention The electric connection may only be made by authorised qualifie...

Page 3: ...No 039 974 5 NT100 Order No 040 096 The control and the operating unit with frame are supplied as one shipping unit The power supply is a separate shipping unit A switch box is to be provided by the c...

Page 4: ...4 Dimensions in mm Operating element with frame 55 25 55 88 11 Shipping unit and dimensions EN Power supply Example 5 NT18 not in the scope of delivery...

Page 5: ...ocation a simple 42 mm deep switch box will be sufficient Installation EN Control unit Switch box 90mm Power supply to be connected according to circuit diagram Attention Connect control unit and oper...

Page 6: ...Plug the operating element and the control unit together correctly using the colour marked wire of the connection cable for orientation Operating element View from behind without frame Control unit C...

Page 7: ...f 3 mm e g electric fuse Each electric circuit of this ventilation system must be fitted with a resi dual current protection e g FI switch RCCB Electrical connection only by a specialist Additional in...

Page 8: ...e Coding switch 3 5 C EN red blue S1 purple S2 purple Colour marked wire 12 Power supply e 5 NT18 6 5 NT60 10 5 NT100 10 10 Maximum number of connectable ventilation units rd bl pl rd bl pl device 1 3...

Page 9: ...l connection ego Coding switch 9 EN Connection board ego S1 S2 12 V Colour marked wire Maximum number of connectable ventilation units Power supply ego 5 NT18 3 5 NT60 5 5 NT100 5 5 red blue S1 purple...

Page 10: ...ical connection RA 15 60 Coding switch 0 EN Steuerung red blue S1 purple RA 15 60 12 V Power supply RA 15 60 5 NT18 1 5 NT60 1 1 5 NT100 1 1 1 Maximum number of connectable ventilation units Colour ma...

Page 11: ...T Coding switch E EN 12 V Steuerung The connection of the respective device type to the 5 UNI FT can be found in the installation in structions for the 5 UNI FT device 2 e g ego device 1 e g e S1 S2 0...

Page 12: ...ir only in pure operation with heat recovery stage 4 also runs at 20 m h in reversing operation unpaired operation works only with e 60 devices Connect one device to S1 and two devices to S2 Specify t...

Page 13: ...coding switch again according to the table on the previous page The regulation takes place almost continuously and in an intelligent way in which a distinction is made between permanently high relativ...

Page 14: ...stage 3 50 70 45 75 55 65 Without base ventilation Base ventilation OFF during the night possible max 8 hours Landlord protection permanent base vent on lowest stage 1 2 3 4 Special function deactivat...

Page 15: ...ime of the intensive ventilation Setting of the stage for the intensive ventilation Activating or deactivating the night time reduction Defining the runtime of the night time reduction Defing the acti...

Page 16: ...ach pressure on the button increases the stage by one After the highest stage the lowest stage or OFF follows again When the automatic mode is activated manual changes of the ventilation stage are val...

Page 17: ...age and the LEDs light up with low brightness The system automatically returns to the previously set mode after the set time has elapsed factory setting 8 hours The LEDs light up again with full brigh...

Page 18: ...by a triple flashing of the Event LED Symbol descriptions The factory settings are as follows Device type e Automatic mode the lowest stage in humidity sensitive mode is the lowest ventilation stage...

Page 19: ...emove the inner screen of the ventilation unit remove the filter insert the new or cleaned filter put the inner screen back on Reset the filter monitoring display by pressing the Event button for thre...

Page 20: ...20 E312 10 21 Notes EN LUNOS Germany LUNOS L ftungstechnik GmbH Phone 49 30 362 001 0 f r Raumluftsysteme Fax 49 30 362 001 89 Wilhelmstr 31 info lunos de 13593 Berlin Germany www lunos de...