11
Technical data
EN
Shipping units
Please check the delivery for completeness and mint condition
Electrical connection
Supply voltage:
12 VDC SELV
Connected load:
28 W (start
-
up)
Protection class:
II
Power consumption:
Protection type:
IP 20
Low stage (15 m³/h)
0,6 W
Middle stage (30 m³/h)
1,3 W
High stage (60 m³/h)
7,2 W
Assembly tube
Outer grille
Tube DA 160 mm
Plaster protection cap
RA 15
-
60 Built
-
in device
Inner screen
Type 9/IBE
Sound insulation ring
Star
-
shaped sound
absorbers
Fan with cable
Sound
insulation mat
Attention! The filter is included in
the shipping unit
RA 15
-
60 built
-
In device
Alternative inner screens see
pricelist or available on request
Alternative external closures see pricelist
or available on request!
Operating range
Temperature range:
-
15°C to +40°C
Usable with relative humidity levels of up to 65% in the interior area (not condensing). When usage limits are exceeded,
switch off the device and close the inner screen. Ensure fresh air supply by window ventilation.
12
Installation examples
EN
Dimensions in
mm
Standard length
500 mm
Star
-
shaped sound absorbers Sound insulation mat Outer grille
Inner screen 9/IBE Sound insulation ring Fan
Other installation lengths:
Please observe the
differing number of star
-
shaped sound absorbers
to be inserted!
The pictured order of the
elements in the tube must
always be observed!
The sound insulation mat
must be inserted with the
thicker side towards the
outer grille! If necessary,
shorten the sound
insulation mat from the
outside.
inside
outside