Safety Instructions 

Caution! All work on the time lag unit 
(mains connection and setting of miniature 
switches) must only be carried out when 
power supply has been completely discon-
nected! 
 
Ensure all connection lines are de-
energized before connecting the fan unit to 
the supply voltage! 
(Disconnection from mains with at least 3 
mm contact opening, e.g. electric fuse). 
 
Each circuit connected to the fan must be 
equipped with residual current protection 
(e.g. RCD switch)! 
 
Electrical connections must only be carried 

Additional installations and electrical components in the 
fan are not admissible. 
Connection diagrams for other fan functions available on 

Electrical Connection 

For LUNOS fans without time lag installed 

General: 

Room 
lighting 

Time-lag controlled ventilation on de-
mand: 

Continuous operation of basic ventilation with switch-
able time-lag controlled ventilation on demand 

Deutschland 

LUNOS Lüftungstechnik  

 

     Tel.: 0 30 / 36 20 01 - 0 

GmbH für Raumluftsysteme  

     Fax: 0 30 / 36 20 01 - 89 

Wilhelmstr. 31 

 

 

     E-Mail: [email protected] 

13593 Berlin   

 

 

     Internet: http://www.lunos.de

 

Operating the Unit 
You can switch the following functions 
using the miniature switches: 
 
Interval switching 
If the interval switching is activated, the 
interval meter triggers a start of the fan 
every 4 h after the previous time the fan 
was switched off. The ventilation period is 
then 30 minutes. 
 
Time lag 
The fan continues to operate after switch-
ing off for the respective time set. 
 
Inverse operation 
Fan only starts to operate after room light-
ing has been switched off. The ventilation 
period is then 30 minutes. 
 
Switch-on delay 
Fan only starts 120 sec. or immediately 
after being switched on. 
 
 
Simultaneous installation of basic ventila-
tion in continuous operation of the fan and 
of the time lag for ventilation on demand 
or full load mode (interval/inverse and 
also time lag switching) is possible. 

5/ZII 

5/ZII 

5/ZII 

L2  L1  L    N   F+  F- 

L2  L1  L    N   F+  F- 

Room 
lighting 

Room 
lighting 

E 1

7

4

 0

6

/1