Installation Manual for the Radar-
Based Motion Detector
Type 5/BM Order-No.: 040 082
- Please forward to the user-
Connecting the motion detector
Positioning of the motion detector
Range of the motion detector
vertical
Range of the motion detector
horizontal
Max. 3 m
120 °
120°
Max. 3 m
Caution!
Any assembly work to the ventilation device may only be
carried out after disconnecting the supply voltage! Additional installations
and electrical components in the ventilation unit are not admissable!
Motion detector connected
to the control board and
installed in the grille frame:
Control
Motion detector
Positioning bars
Grille frame
Take off the front cover of the Silvento ec.
Remove the control board from the grille frame by loosening the
fixing screw.
Plug the motion detector with the connector into the control board.
Insert the control board with the connected motion detector into the
grille frame.
Snap the motion detector into place in the positioning bars.
Fasten the control board using the fixing screw.
Put the front cover back on the grille frame.
Motion detector
Connecting the motion de-
tector to the control board:
Control board
Connector
Application
The Motion Detector Type 5 / BM is designed for use in fans of the
series Silvento ec and works only together with a complete unit of this
series. A separate operation is not possible and not allowed.