Lunos 3/UP-AS Technical Information Sheet Download Page 2

 

 

E269 11.18 

Description and functions 

Installation 

 

Technische Daten 

Power supply

 

230 V AC 50 Hz 

Dimensions  
W x H x D 

 

270 mm x 270 mm x variabel

 

Available static pressure 

227 Pa

 

Housing for flush mounting made of UV-stable plastic and Styrofoam coating, sui-
table for outer  wall installation  with rear conical exhaust vent (DN 80-DN 75) and 
leakage-airtight backdraft shutter. 
All  ventilator inserts of the Silvento series can  be inserted into  the flush-mounted 
housing. 
The housing is available in different thicknesses or can be extended to fit any exis-
ting wall thickness using Styrofoam adapter. 
 
Versions available: 
 

3/UP-AS10,7

 

         

Housing with rear exhaust vent and Styrofoam coating (107 mm depth), sound in-
sulation, plaster protection cap and mains supply terminal 
 

3/UP-A17,5        

Same as 3/UP-AS10,7, additionally with wall duct 9/J30 and Styrofoam adapter to 
extend the above-mentioned housings by 53 mm each 

Order No. 039 841

 

The installation of the housing is made by flush finish with the wall and ventilation 
using the wall duct directly through the outer wall.  
 
Please observe the installation manualhave the electrical connection of the fan per-
formed by a qualified professional. 

Note 

Products  and  illustrations  may  vary  slightly.  Due  to  continuous  product  develop-
ment and/or several suppliers e.g. for raw materials, colours, among other things, 
may vary slightly (not for visible parts) or be shown differently in brochures. 