- 20 -
Permanent temperature setting:
1. Turn the thermostat clockwise to the biggest dot.
2. When the desired room temperature has been reached, turn the regulator counter-clockwise
to the stopping point and hold down the key position.
3. The purpose of this function is to save energy.
Thermal safety shut-down
The device is equipped with a safety shut-down feature that is activated when the device becomes too
hot (e. g. if ventilation slots are blocked). For safety reasons, the device cannot be reset automatically.
Before using the device again, separate it from the socket for at least 15 minutes, to allow it to cool.
Power connection
Danger!
Electrical installation work may only be carried out by authorised specialists. If you need an
additional socket for the device, please contract a specialist electrician.
Replacing lamps:
1. Two lamps are located behind the back panel.
2. To access the lamps, you must remove the two screws that hold the back panel in place.
3. Slide out the panel to remove it.
4. Remove the damaged lamp by pulling it from the lamp socket.
5. Replace the damaged lamp with a 25W G9 halogen lamp. Make sure that you do not touch the
lamp with your bare hands and ensure that it is installed firmly.
6. Re-attach the back panel using the two screws.