![Lumitron Lumitron ECS-320A Developer'S Manual Download Page 40](http://html1.mh-extra.com/html/lumitron/lumitron-ecs-320a/lumitron-ecs-320a_developers-manual_1949362040.webp)
S
ERIAL
I
NTERFACE
D
EVELOPERS
G
UIDE
ErrorData [1] Value read back.
ErrorData [2] Test mask.
ErrorData [3] Lower 16 bits of memory address.
ErrorData [4] Upper 16 bits of memory address.
6.6.6 Force ‘1’ Test
This error is set during operational tests.
Data from CameraConfig.camErrors:
ErrorCode: ERR_FORCE_ONE define.
ErrorSubCode: No subcode.
ErrorCount: a count of the total number of errors since boot.
ErrorData [0] Value expected (0x2000).
ErrorData [1] Value read back.
ErrorData [2] Test mask.
ErrorData [3] Lower 16 bits of memory address.
ErrorData [4] Upper 16 bits of memory address.
6.6.7 Force Count Test
This error is set during operational tests.
Data from CameraConfig.camErrors:
ErrorCode: ERR_FORCE_COUNT define.
ErrorSubCode: No subcode.
ErrorCount: a count of the total number of errors since boot.
ErrorData [0] Value expected.
ErrorData [1] Value read back.
ErrorData [2] Test mask.
ErrorData [3] Lower 16 bits of memory address.
ErrorData [4] Upper 16 bits of memory address.
6.6.8 Force Count Coadd Test
This error is set during operational tests.
Data from CameraConfig.camErrors:
ErrorCode: ERR_FORCE_COADD define.
ErrorSubCode: No subcode.
ErrorCount: a count of the total number of errors since boot.
ErrorData [0] Value expected.
ErrorData [1] Value read back.
ErrorData [2] Test mask.
ErrorData [3] Lower 16 bits of memory address.
34