www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Cable Gauge Tables - Continued
4
The DMX cable can be extended, contact your dealer for details of light extension cables.
The light power cable can be extended, however the correct cable gauge should be used. See the tables below.
The tables below give the minimum cable gauge required depending on the supply voltage, and distance from the power
source to the lights. Please ensure that the correct cable gauge is used in the installation
Each light must be individually fused
Fuse Table
Model
TIX802
TIX1602
12V
15A
Fuse Rating
24V
7.5A
N/A
10A
Model
TIX802
TIX1602
14AWG
Gauge
Length of Cable
12V
Do Not Extend
14AWG
N/A
24V
32ft
30ft
AWG to Metric conversion table
AWG Size
Cross sectional Area
Cable diameter
10
8
6
4
18
16
14
12
2
5.2mm²
8.3mm²
13mm²
20mm²
1mm²
1.3mm²
2.0mm²
3.3mm²
33mm²
2.5mm
3.2mm
4.1mm
5.1mm
0.8mm
1.3mm
1.6mm
2.0mm
6.5mm
Note : The cable distance there and back has been taken into consideration in these calculations.
DMX Extension
Part Number
24-0077
24-0078
1m
5m
15m
24-0099