Product Support

LED Status

No LED light on driver

Solid LED

Flashing 5 times

Meaning

No power to driver

Power On

Driver cannot detect light

Action to take / Things to check

Check fuse / breaker

Check connections

Check voltage at input to driver connections

Driver is receiving voltage and operating properly

Check the switch is operating correctly
Check power connection to light

Check the connection on the back of the light (if present)

If a light does not switch on, or function normally it should be disconnected from the power source

LUMISHORE Ltd warrants the lighting system to be free from defects in workmanship for a period of three 
years, starting from the date of original purchase. Should your lighting system have a problem during this 
period, please contact your dealer as soon as you become aware of the defect.

Misuse, abuse, improper installation, neglect, improper shipping, damage caused by disasters (e.g. fire, 
flood and lightning), installation by unqualified personnel, unauthorized repair or modification will void 
this warranty. For the avoidance of confusion and doubt, non compliance with all installation, maintenance 
and operating instructions in this document constitute non conformance with warranty terms.

Full warranty details are available at www.lumishore.com.

TESTING THE LIGHTS

The underwater lighting system should always be tested before the boat goes back in the water. Check that 
each light comes on, and all lights change in sequence as per the system operation section above. See the 
problem solving guide for advice on resolving any issues.

WARRANTY

TROUBLESHOOTING

In the event of one or more of the lights not lighting up then check the LED status on the driver. The LED 
will either be continually ON (healthy), OFF (no power to driver) or flashing. Please refer to the table 
below for what the number of flashes means and what action to take..

In the event of an issue then:

1.     Check the operation of the light and driver with only that light and driver powered
2.     If the light is still not operational then swap the driver with the flashing LED with a driver which is                                       
known to be working and re-test the light
3.     Test the driver with a known good light
4.     This will determine if the issue is with the light or the driver
5.     Record the serial numbers of both the light and the driver and contact your local dealer

Summary of Contents for SUPRA SY225

Page 1: ...esults install the lights between 2 5ft 0 8m and 6 5ft 2m apart Never try to install or remove light with the vessel in the water Lights should not be exposed to any temperatures in excess of 150 F 65 C For example next to hot engine components or where exhaust emissions could be expelled onto the light while underwater 1 Congratulations You have purchased a LUMISHORE advanced technology underwate...

Page 2: ...er can be configured to give any combination of the following modes of operation See page 4 in this manual for instructions on how to connect the drivers to give the required functions Note These instructions cover SUPRA White Blue SUPRA Cold White Warm White depending on which are being installed Solid White Cold White Solid Blue Warm White Solid White Cold White or Solid Blue Warm White Selectab...

Page 3: ...r end The input voltage cable used should be a suitable marine approved mains cable For details on the light installation please refer to the light installation instructions Input Voltage Range 90 240VAC 50 60Hz Maximum Input Current 2 1Amp Input Wiring Brown Wire LIVE Blue Wire NEUTRAL Green Yellow EARTH Function Port Light Port www Lumishore com Lumishore UK Unit 2 Technium 1 Kings Road Swansea ...

Page 4: ...d by a connector Function Port Light Port 2 1 7 6 5 4 8 3 WHITE COLD WHITE ONLY 2 and 8 5 and 6 2 1 7 6 5 4 8 3 BLUE WARM WHITE ONLY 3 and 8 5 and 6 Move Jumper Positions HOW TO FIT A SWITCH FOR WHITE COLD WHITE AND BLUE WARM WHITE SELECTION Using the optional Switch Assembly 39 0146 and the supplied Y Splitter Cable 24 0208 The Supra Mains driver can be configured to work with an external switch ...

Page 5: ...L U E G R E E N Y E L LO W LED STATUS x3 LIGHT TEMP x5 NO LIGHT BLINK ATRB OK Label PN 21 0214 REV A Model No HLG 185H 42B AC DC INTELLIGENT COMBI DRIVER S E LV IP67 T Ü V R he inla nd P roduc t S a fe ty B AU A R T G E P R Ü F T T Y P E A P P R OV E D 90 C 60 C t t c a LIGHT CNCT DIM CNCT LUMISHORE PRODUCT CODE CONFIGURED FOR MADE IN CHINA 90w XX XXXX I N P U T 90 305V A C 2 1 A 47 63Hz A C L B R...

Page 6: ... 12volts 12 V DC Signal Generator Note In this mode when the lights are initially switched ON they will light up and wait for a signal Once they receive this signal they will respond NO signal OFF Signal ON This will remain the case until the lights are switched off and on again using the switch 1 10v Dimming Input The Lights can be dimmed using a 3rd party 1 10volt dimming module Connect the 1 10...

Page 7: ...nqualified personnel unauthorized repair or modification will void this warranty For the avoidance of confusion and doubt non compliance with all installation maintenance and operating instructions in this document constitute non conformance with warranty terms Full warranty details are available at www lumishore com TESTING THE LIGHTS The underwater lighting system should always be tested before ...

Reviews: