www.Lumishore.com
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
2
Note : Black wire from each light and LUX Module should connect to common ground
Max 16 lights per LUX Light Module
10-31v
GND
Cut & Isolate
RED & BLK
LUX Light
Module
Switch (Momentary)
MFD Control
(Optional)
Lumi-Link
Command Center
1
6
2
5
3
4
RED
10-31v
BLK
GND
RED
10-31v
BLK
GND
RED
10-31v
BLK
GND
RED
10-31v
BLK
GND
RED
10-31v
BLK
GND
RED
10-31v
BLK
GND
Wiring Diagrams:
Wiring should be carried out as per ABYC guidelines. The Lumishore Flood Light 18” will operate with a simple On/Off switch, it
can also be controlled by MFD via LUX Light Control Module and Lumi-Link Command Center. For further electrical installation
instructions and wiring diagrams please refer to the LUX Light Module installation guide (45-0145). Each lighting circuit must
be fused accordingly.
MFD Control via LUX Light Control Module
Light Operation (Latching switch):
1. Turn switch ON to power light at full power.
2. Toggle switch once to begin dimming cycle.
3. Toggle switch again to pause dimming cycle.
4. Turns switch OFF for 5 seconds to restart at full power
Switch (Latching)
Yellow
(No connect)
Fuse
Yellow
(No connect)
Single switch wiring - No MFD control via LUX Light Control Module
RED - 10-31V
BLK - GND