ROUTINE TEST RECORD
Type Test
Year 1
Year 2
Year 3
Year 4
Year 5
Signed
Date
Signed
Date
Signed
Date
Signed
Date
Signed
Date
Functional 1
Functional 2
Functional 3
Functional 4
Functional 5
Functional 6
Functional 7
Functional 8
Functional 9
Functional 10
Functional 11
3hr Duration 12
Installation Engineers Contact Details:
Luminaire Reference / Location
Name:
Tel:
Luminaire Details:
Full Recharge Duration
24 Hours
Emergency Duration
3 Hours
Lamp Type
LED
Sutton Batten
This luminaire is warranted for a
period of 5 years from the date of
purchase.
The backup battery
pack in the emergency version
is warranted for a period of 12
months. The warranty could be
invalidated should the light fitting
not be installed according to these
instructions, outside the scope of
the specification or the product
has been altered or tampered with
in any way. Please see website for
terms and conditions.
Standard
-20 to +40ºC
Emergency 0 to +25ºC
1. Connect incoming earth cable to ‘Earth’ terminal on connector block.
2. Connect incoming neutral cable to ‘Neutral’ terminal on connector block.
3. For the emergency unit to work correctly, please ensure that an
uninterrupted permanent live feed is present and is connected directly
to the ‘Permanent Live’ terminal of the mains terminal block. Please
ensure there are no switches, PIRs etc within the permanent live feed,
constant switching of the emergency pack could result in premature
battery failure.
4. Connect incoming switched live cable to the terminal marked
“Switched Live”
NOTE: If there is no switch live feed and the unit has a microwave sensor,
simply bridge across from the “Permanent Live” to the Switch Live” on the
mains terminal block.
5. There should be a loose flying lead connected to the battery. This needs
to be attached to the flying lead from the emergency control unit.
6. Following power up the green LED indicator should illuminate to indicate
charging. If power to the unit is disrupted or isolated, the unit indicating
green LED will switch off, triggering the emergency LEDs to illuminate.
7. Please allow 24 hours charge before first emergency test.
The self-test version of emergency is fitted with control gear that will carry out
periodic functional tests every 1 month and full duration test every 12 months.
Technical Helpline: +44 (0)1507 328031
Wiring instructions for units equipped
an with EMERGENCY function
Self-Test EMERGENCY function
DISPOSAL
WARRANTY
PRODUCT TEMP SPECIFICATION
Detection Range:
This determines the effective
range of the motion. Note that reducing the
sensitivity will also narrow the detection range.
Hold Time Duration:
This determines the
time the fitting remains at 100% illumination
following motion detection.
Daylight Setting:
This setting holds off the 100%
light output should there be sufficient daylight.
STANDARD ON/OFF SENSOR
MICROWAVE SENSOR SETTINGS
STEP DIM DRIVER SETTINGS
DETECTION AREA
1
2
ON ON
100%
OFF ON
75%
ON OFF
50%
OFF OFF
25%
OUTPUT CURRENT SETTING
Output Current (mA) S1
S2
S3
1200
ON ON ON
1050
ON ON
-
900
ON
-
-
800
-
-
-
DAYLIGHT SENSOR
Daylight Sensor S1
S2
S3
Disable*
ON ON ON
100Lux
ON ON
-
50Lux
ON
-
ON
30Lux
-
ON ON
10Lux
-
-
-
STAND-BY-PERIOD
Stand-by-Period S4
S5
1 Min
ON ON
5 Min
ON
-
25 Min
-
ON
+∞
-
-
SENSITIVITY
Sensitivity
S1
S2
100%
ON ON
75%
ON
-
50%
-
ON
25%
-
-
HOLD TIME
3
4
5
ON ON ON
5S
OFF ON ON
30S
ON OFF ON
90S
OFF OFF ON
5Min
ON ON OFF
20Min
OFF OFF OFF
30Min
DAYLIGHT
6
7
8
ON ON ON
2Lux
ON ON OFF
10Lux
OFF ON OFF
30Lux
ON OFF OFF
50Lux
OFF OFF OFF
Disable
Part No.
Description Watts L
(mm)
W
(mm)
H
(mm)
LF
(mm)
Weight
430039 / 430045 4ft Twin 38W 1220 64
62 1016 1.25Kg
430041 / 430047 5ft Twin 50W 1524 64
62 1320 1.55Kg
430043 / 430049 6ft Twin 60W 1829 64
69 1625 1.80Kg
430038 / 430044 4ft Single 19W 1220 64
62 1016 1.25Kg
430040 / 430046 5ft Single 27W 1524 64
62 1320 1.55Kg
430042 / 430048 6ft Single 38W 1829 64
69 1625 1.80Kg
SUTTON BATTEN DIMENSIONS
*Sensor is disabled and will not detect daylight
+∞
Lights remain constant at low level
Set via detachable sensor
Emergency lighting luminaries must be installed and maintained in
accordance with the emergency lighting standard BS 5266-1
Revision 2 - February 2022
LENGTH
LF
W
H
Fault/Test/Status
Reason
Battery fully charged
and operational
Standard daily use
Battery Charging
Initial charge /
battery topping up
Battery Failure
Battery is disconnected or
damaged/faulty
Duration Test Failure
Maintenance check required
by qualified engineer
Automatic Testing - Function
5 minute test (Every 30 days)
Self-testing in
operation
Automatic Testing -
Duration test is 3 hours
(every 12 months)
Self-testing in
operation
Charge Indicator Status
Battery Fully Charged
and Operational
Battery Charging
Auto Test
5 Min
(every 30 days)
Auto Test
3 Hours
(every 12 months)
Duration Test Failure
1 Sec ON
1 Sec OFF
3 Sec ON
3 Sec OFF
3 Sec ON
1 Sec OFF
0.5 Sec ON
0.5 Sec OFF
Battery
Disconnected/Faulty
The light source of this unit is not
replaceable; when the light source
reaches its end of life the whole
luminaire shall be replaced.
Disassemble instructions for end of
life disposal available on website.
Disposal of Electronic Equipment
WEEE Directive 2002/96/EC This
product falls within the scope of
the Waste Electrical & Electronic
Equipment Directive (WEEE), which
means the product should not be
disposed of as normal household
waste. Please recycle where
facilities exist or check with your
Local Authority. RoHS – All
components and materials used in
this product are RoHS 2002/95/EC
compliant.
Specifications may change from time
to time. The information contained
in this leaflet is for guidance only
and should not be considered as
always accurate and should be
treated as not representative.
** Please see our website for more detailed information on warranty.
This product contains a light source of energy efficiency Class E.
EMERGENCY FITTINGS ONLY. EARTH CONNECTION REQUIRED.
L - LIVE (SW)
= Brown
N - NEUTRAL
= Blue
L1 - PERMANENT LIVE (PL)
= Black
- EARTH
= Green/Yellow