ROUTINE TEST RECORD

Type Test

Year 1

Year 2

Year 3

Year 4

Year 5

 

Signed

Date

Signed

Date

Signed

Date

Signed

Date

Signed

Date

Functional 1

Functional 2

Functional 3

Functional 4

Functional 5

Functional 6

Functional 7

Functional 8

Functional 9

Functional 10

Functional 11

3hr Duration 12

Installation Engineers Contact Details:

Luminaire Reference / Location

Name:

Tel:

Luminaire Details:

Full Recharge Duration 

24 Hours

Emergency Duration 

3 Hours

Lamp Type 

LED

Sutton Batten

This luminaire is warranted for a 

period of 5 years from the date of 

purchase.

 The backup battery  

pack in the emergency version 

is warranted for a period of 12 

months. The warranty could be 

invalidated should the light fitting 

not be installed according to these 

instructions, outside the scope of 

the specification or the product 

has been altered or tampered with 

in any way. Please see website for  

terms and conditions.  

Standard 

-20 to +40ºC

Emergency  0 to +25ºC

1.  Connect incoming earth cable to ‘Earth’ terminal on connector block.
2.  Connect incoming neutral cable to ‘Neutral’ terminal on connector block.
3.  For the emergency unit to work correctly, please ensure that an  

  uninterrupted permanent live feed is present and is connected directly  

  to the ‘Permanent Live’ terminal of the mains terminal block. Please  

  ensure there are no switches, PIRs etc within the permanent live feed, 

  constant switching of the emergency pack could result in premature 

  battery failure. 
4.  Connect incoming switched live cable to the terminal marked  

  “Switched Live”

NOTE: If there is no switch live feed and the unit has a microwave sensor, 

simply bridge across from the “Permanent Live” to the Switch Live” on the 

mains terminal block.

5.  There should be a loose flying lead connected to the battery. This needs  

  to be attached to the flying lead from the emergency control unit. 
6.  Following power up the green LED indicator should illuminate to indicate 

  charging. If power to the unit is disrupted or isolated, the unit indicating 

  green LED will switch off, triggering the emergency LEDs to illuminate.
7.  Please allow 24 hours charge before first emergency test.

The self-test version of emergency is fitted with control gear that will carry out  

periodic functional tests every 1 month and full duration test every 12 months. 

Technical Helpline: +44 (0)1507 328031

Wiring instructions for units equipped  

an with EMERGENCY function

Self-Test EMERGENCY function

DISPOSAL

WARRANTY

PRODUCT TEMP SPECIFICATION

Detection Range:

 This determines the effective 

range of the motion. Note that reducing the 

sensitivity will also narrow the detection range.

Hold Time Duration:

 This determines the  

time the fitting remains at 100% illumination 

following motion detection.

Daylight Setting:

 This setting holds off the 100% 

light output should there be sufficient daylight.

STANDARD ON/OFF SENSOR

MICROWAVE SENSOR SETTINGS

STEP DIM DRIVER SETTINGS

DETECTION AREA

1

2

 

ON ON

100%

OFF ON

75%

ON OFF

50%

OFF OFF

25%

OUTPUT CURRENT SETTING

Output Current (mA) S1

S2

S3 

1200

ON ON ON

1050

ON ON

-

900

ON

-

-

800

-

-

-

DAYLIGHT SENSOR

Daylight Sensor S1

S2

S3 

Disable*

ON ON ON

100Lux

ON ON

-

50Lux

ON

-

ON

30Lux

-

ON ON

10Lux

-

-

-

STAND-BY-PERIOD

Stand-by-Period S4

S5

1 Min

ON ON

5 Min

ON

-

25 Min

-

ON

+∞

-

-

SENSITIVITY

Sensitivity

S1

S2

100%

ON ON

75%

ON

-

50%

-

ON

25%

-

-

HOLD TIME

3

4

 5

 

ON ON ON

5S

OFF ON ON

30S

ON OFF ON

90S

OFF OFF ON

5Min

ON ON OFF

20Min

OFF OFF OFF

30Min

DAYLIGHT

6

7

 8

 

ON ON ON

2Lux

ON ON OFF

10Lux

OFF ON OFF

30Lux

ON OFF OFF

50Lux

OFF OFF OFF

Disable

Part No.

Description Watts L

 (mm)

(mm)

(mm)

LF 

(mm)

Weight

430039 / 430045 4ft Twin 38W 1220 64

62 1016 1.25Kg

430041 / 430047 5ft Twin 50W 1524 64

62 1320 1.55Kg

430043 / 430049 6ft Twin 60W 1829 64

69 1625 1.80Kg

430038 / 430044 4ft Single 19W 1220 64

62 1016 1.25Kg

430040 / 430046 5ft Single 27W 1524 64

62 1320 1.55Kg

430042 / 430048 6ft Single 38W 1829 64

69 1625 1.80Kg

SUTTON BATTEN DIMENSIONS

*Sensor is disabled and will not detect daylight

+∞ 

Lights remain constant at low level

Set via detachable sensor

Emergency lighting luminaries must be installed and maintained in 

accordance with the emergency lighting standard BS 5266-1

Revision 2 - February 2022

LENGTH

LF

W

H

Fault/Test/Status

Reason

Battery fully charged  

and operational

Standard daily use

Battery Charging

Initial charge /  

battery topping up

Battery Failure

Battery is disconnected or 

damaged/faulty

Duration Test Failure

Maintenance check required  

by qualified engineer

Automatic Testing - Function  

5 minute test (Every 30 days)

Self-testing in  

operation

Automatic Testing -   

Duration test is 3 hours  

(every 12 months)

Self-testing in  

operation

Charge Indicator Status

Battery Fully Charged 

and Operational

Battery Charging

Auto Test 

5 Min

 

(every 30 days)

Auto Test 

3 Hours 

(every 12 months)

Duration Test Failure

1 Sec ON

1 Sec OFF

3 Sec ON

3 Sec OFF

3 Sec ON

1 Sec OFF

0.5 Sec ON

0.5 Sec OFF

Battery  

Disconnected/Faulty

The light source of this unit is not  

replaceable; when the light source  

reaches its end of life the whole  

luminaire shall be replaced.
Disassemble instructions for end of 

life disposal available on website.
Disposal of Electronic Equipment 

WEEE Directive 2002/96/EC This 

product falls within the scope of 

the Waste Electrical & Electronic 

Equipment Directive (WEEE), which 

means the product should not be 

disposed of as normal household 

waste. Please recycle where  

facilities exist or check with your 

Local Authority.  RoHS – All  

components and materials used in 

this product are RoHS 2002/95/EC 

compliant.
Specifications may change from time 

to time. The information contained 

in this leaflet is for guidance only 

and should not be considered as  

always accurate and should be  

treated as not representative.

** Please see our website for more detailed information on warranty.

This product contains a light source of energy efficiency Class E.

EMERGENCY FITTINGS ONLY. EARTH CONNECTION REQUIRED.

L   -  LIVE (SW)

 = Brown

N   -  NEUTRAL

 = Blue

L1  -  PERMANENT LIVE (PL)

 = Black

      -  EARTH 

= Green/Yellow