6

 

 

T

EMPERATURE PROTECTIVE DEVICES

 

For hazardous safety and lifetime optimization the RLX D LED floodlight is equipped with several 
temperature protective devices. Two individual temperature controls may have influence on the use of the 
floodlight.  

Automated Temperature Control  

A set of temperature sensors are distributed on the LED circuit board to protect the LEDs and material 
lifetime in high ambient temperatures. This circuit will automatically adjust the LED current as the 
temperature rises. It is important to note that this circuit will not have influence on the light output before 
the temperature reaches material limits. 

Manual Resettable Temperature Protection 

The floodlight is equipped with a manual resettable temperature protective device, which will trigger and 
turn off the lamp if it is heated with an external heat source or if another fatal error occurs. For the 
protective device to reset, the power input must be turned OFF and ON and the temperature must be 
decreased. 

7

 

  

M

AINTENANCE

 

The product is made to be maintenance free and only occasional cleaning without solvent is recommended 
to ensure light output and cooling. 

Do not paint. Material combination and surface treatment has been carefully selected to make the RLX D 
floodlight withstand corrosive environments even with damage to the surface treatment. The assembled 
unit complies with ISO9223/12944 and has a rated c5m corrosion class.   

Damages to seals, gasket, breather drain, cable glands, entries, front glass, housing or terminals may 
invalidate the certificate. In uncertain cases, please contact Luminell for clarification.  

8

 

 

T

ROUBLESHOOTING

 

Problem  

Possible reason 

Possible solution 

Does not turn on. 

The floodlight may be exposed to 
external heat, causing the temperature 
protection to activate.  

Remove external heat source and 
disconnect and reconnect power. 
See section 10 Temperature 
protective devices. 

Turns off 
automatically. 

A combination of high ambient 
temperature and reduced airflow may 
cause the floodlight to heat up and turn 
off. 

Disconnect and check for sufficient 
air flow. 

Seems to have 
reduced light output. 

High ambient temperature see section 
10 or an unintended DIM signal or 
connection on the DIM connections.  

Check ambient temperature and dim 
control connection. 