Lumina Power LDD-1000 Series User Manual Download Page 13

02001027 
Rev 1 ECO 7062 

Operation Manual: 

LDD-600/1000/1500-XX-YY 

Page 13 of 13 

 

Connections to Analog Interface when using RS-232  

 

Interlock

 function, 

Pin 3

, must be employed whether using LDD analog interface or RS-

232.  None of the other controls in the Analog interface need be utilized when using the 
RS-232 optional interface.   
 

Analog Connector Type:  15 pin D-sub Female 

(Refer to Figure 2, LDD Interface Schematic) 

 

Pin  # 

Pin Name 

Functional Voltage 

Level  

Description 

Interlock  

(input) 

Open = OFF 

Connect to GND = RUN        

The Interlock function can be 

connected to external interlock 

switches such as door or overtemp 

switches.  Must be used with RS 
Interface
 

 

 
 
 
 
 
Servicing LDD-600/1000/1500 Diode Drivers 

 
LDD-600/1000/1500 units have no serviceable parts.  Do not attempt to repair or service 
this unit in the field.  For further information, contact Lumina Power at 978-241-8260. 
 
 
 
 
 
 
 
 
 
 
 
 
 

Lumina Power, Inc. 

26 Ward Hill Dr.,  Bradford,  MA 01835 

Ph:  978-241-8260   Fx: 978-241-8262 

www.luminapower.com

 

[email protected]

 

 

Summary of Contents for LDD-1000 Series

Page 1: ...tage capability depending on the user s requirements LDD power supplies will deliver current as programmed into any load providing the voltage requirements of that load do not exceed the maximum rated...

Page 2: ...s 5 LDD 600 1000 1500 Interface 7 INSTALLATION AND OPERATION 9 Optional RS 232 Protocol 12 Tables and Figures LDD Laser Diode Power Supply Block Diagram 4 LDD 600 1000 1500 Outline Drawing 6 LDD 600 1...

Page 3: ...er This inverter boosts the input voltage to 400VDC In the process of boosting the input AC voltage the input AC current is adjusted so that is always in phase with the input AC voltage Without this p...

Page 4: ...e EMI noise and a reduction in overall system heatsink requirements Output Circuit The output filter is a two stage RC filter designed to keep ripple and output noise very low Control Circuit The cont...

Page 5: ...rent Voltage Monitor 0 10V for 0 Max Voltage Performance Rise Fall Time 600usec 10 to 90 Full Current Current Regulation 0 5 of Maximum output current Temperature Drift 0 5 over temperature range afte...

Page 6: ...02001027 Rev 1 ECO 7062 Operation Manual LDD 600 1000 1500 XX YY Page 6 of 13 Figure 2 LDD 600 1000 1500 Outline Drawing...

Page 7: ...y 5 Vout Monitor output 0 10V 0 Voutmax The output voltage of the supply can be monitored by Vout Monitor 6 Iout Monitor output 0 10V 0 Ioutmax The output current of the supply can be monitored by Iou...

Page 8: ...02001027 Rev 1 ECO 7062 Operation Manual LDD 600 1000 1500 XX YY Page 8 of 13 Figure 3 LDD 600 1000 1500 Interface...

Page 9: ...re 4 Although the user interface is typically designed by the user Lumina Power can provide any assistance necessary to modify interface program and monitor levels See Table 1 and Figure 3 for descrip...

Page 10: ...gram Pin 7 A 0 10V signal results in 0 to Ioutmax as long as the rated compliance voltage of the driver is not exceeded 4 Operating the LDD a AC INPUT POWER CONNECTION Connect AC power connections to...

Page 11: ...ver output current as programmed 5 Monitoring LDD output and performance a Current Monitor Power supply output current can be monitored via pin 6 Iout Monitor A 0 10V signal will represent the output...

Page 12: ...supply and reading back the output current and voltage The output can be turned on and off with a command as well Command Reply Function Pxx xx xx xx cr cr Program output current to max rated output c...

Page 13: ...Interface Schematic Pin Pin Name Functional Voltage Level Description 3 Interlock input Open OFF Connect to GND RUN The Interlock function can be connected to external interlock switches such as door...