3.

 

CCPF-3500/4000-XX Specifications 

XX indicates output voltage with P for positive and N for negative. 

Input 

Voltage 

200 - 240 VAC, single phase 

Current 

22 A maximum at 200 VAC and 18.4A maximum at 240 VAC 

Frequency 

47 - 64Hz 

Output 

Power: 

3500 J/s average charge rate for full discharge PFN 
4000 J/s maximum charge rate for reservoir charging 
See section 5 Typical Applications below 

Output Voltage 

Fixed voltage between the ranges of 400VDC – 4.0kVDC 
(factory configured, contact factory for voltages > 4kVDC) 

Polarity 

Positive or Negative (factory configured) 

Efficiency 

>80% at full output 

Regulation: 

0.5% @100Hz 

Aux. Output  

+24VDC @ 3A (optional feature) 

Interface 

 

Connector 

15 Pin “D” Sub Female 

Voltage Program 

0-10V for 0-Max Voltage 

Voltage Monitor 

0-10V for 0-Max Voltage 

Inhibit/Reset 

Input, low level (high level optional, contact factory) 

End of Charge  

Output indication 

Overvoltage  

Output indication 

Overtemp 

Output indication 

Overload 

Output indication 

+15V Aux Power 

Environment 

Operating Temp 

0 to 40 

o

Storage 

-20 to 85 

o

Humidity 

0 to 90% non-condensing 

Cooling 

Forced air 

Altitude and Pressure 

2000 meters maximum, 80 to 103 kPa 

Dimensions

 

Please see Figure 3, CCPF-3500 Mechanical Outline Drawing 

Outline 

14.2 inch length, 5.5 inch wide, 6.0 inch high  
(does not include mounting flanges or electrical terminals) 

 

Summary of Contents for CCPF-3500 Series

Page 1: ...4 Rev 1 CCPF 3500 XX User Manual Page 1 of 15 26 Ward Hill Ave Bradford MA 01835 Phone 978 241 8260 Fax 978 241 8262 USER MANUAL CCPF 3500 XX CCPF 4000 XX 3 5 to 4 0 kJ s Capacitor Charging Power Supply Series ...

Page 2: ...CCPF with a pulse forming network PFN 9 5 2 Using a CCPF with a partial discharge network Reservoir Charging 10 5 3 Using a CCPF with multiple PFNs or capacitors 11 6 Warnings 12 7 Installation 13 8 Product Limited Warranty 14 9 Service 15 Tables and Figures Table 1 CCPF Interface 6 Table 2 CCPF Connections 13 Figure 1 CCPF 3500 Block Diagram 3 Figure 2 CCPF 3500 Interface Schematic 7 Figure 3 CCP...

Page 3: ...ltage As an example a CCPF 3500 configured for 1000V maximum output voltage is designated as a CCPF 3500 1P where P indicates a positive output which is the standard polarity An optional 24VDC output is available for auxiliary power The CCPF takes AC input from 200 240VAC 50 60 Hz and rectifies it by the input rectifier bridge The rectified voltage is boosted to non isolated 400 VDC by the Power F...

Page 4: ... Lumina Power Inc are qualified to service this equipment High Voltage Present This power supply produces lethal high voltages Only service personnel of Lumina Power Inc are qualified to service this equipment Only qualified service personnel are permitted to install this power supply Chassis Ground This symbol where the protective earth ground connection is located ...

Page 5: ...egative factory configured Efficiency 80 at full output Regulation 0 5 100Hz Aux Output 24VDC 3A optional feature Interface Connector 15 Pin D Sub Female Voltage Program 0 10V for 0 Max Voltage Voltage Monitor 0 10V for 0 Max Voltage Inhibit Reset Input low level high level optional contact factory End of Charge Output indication Overvoltage Output indication Overtemp Output indication Overload Ou...

Page 6: ...put 0 10V 0 Vout max Output is programmed externally with a 0 to 10V signal for 0 to Voutmax See note 1 Note Accuracy and linearity will be compromised when operating below 20 of the max value 6 OVERVOLTAGE OVERLOAD NO LOAD STATUS INDICATOR output High OK 15V Low Overload 0 5V When the output is open or shorted circuited or if the capacitor can t be fully charged to the programmed level in a given...

Page 7: ... 2 CCPF 3500 Interface Schematic Notes 1 Analog voltage range of 0 5V available per customer request 2 Other interface configurations are available to conform to older capacitor charger models or customer requests contact Lumina Power for any interface changes ...

Page 8: ...02100004 Rev 1 CCPF 3500 XX User Manual Page 8 of 15 Figure 3 CCPF 3500 Mechanical Outline Drawing ...

Page 9: ...N capacitor to the programmed value and then transmit an END OF CHARGE signal to the user Before discharging the load capacitor into the PFN the CCPF should be disabled via the INHIBIT function Once the PFN is completely discharged and the SCR has completely turned off the charging function can be ENABLED via the INHIBIT function and the CCPF will charge the capacitor again to the programmed value...

Page 10: ...ng In this application the power supply is ENABLED via the INHIBIT function and charges up the capacitor bank to the programmed voltage The IGBT will deliver short high current pulses to the flashlamp The power supply does not need to be inhibited during this process and continuously maintains the capacitor bank charged ...

Page 11: ... cap from discharge into the other Also a resistor must be in parallel with each diode to help the power supply to see the cap voltage which is now blocked by the diodes Failure to add the parallel resistors will result in over charging the cap as the power supply does not see the real voltage on the caps The diodes must have voltage rated at least 300V higher than the max voltage and 2 times the ...

Page 12: ...be connected to a supply mains with protective earth Warning Equipment is not suitable for use in presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide Warning These power supplies are not provided with any isolation devices and shall only be used inside other equipment that has means to isolate its circuits electrically from the supply mains on all poles simultaneous...

Page 13: ...note below LGH plug with coax cable rated for at least 150 of maximum output voltage of unit 24V Aux Output optional 2 Pin Tyco Mate N Lok Connector Tyco 35077 1 2 Pos Plug Digikey P N A14279 ND Tyco 350550 1 Contacts Digikey P N A1441 ND Note other connectors or flying lead configuration also available contact Lumina Power for any interface changes Ventilation This unit is forced air cooled via i...

Page 14: ...glect of the Product Use and service of the Product in a manner not in accordance with the Owner s Manual if furnished will likewise cause all obligations under this warranty to cease Repaired or replacement parts are warranted only for the remaining unexpired portion of the original warranty period for the Product After expiration of the applicable warranty period Buyer shall be charged at the th...

Page 15: ...se MJ 08 17 2016 EK This unit contains no user serviceable parts Service and repair should be performed only by qualified personnel from Lumina Power Inc For more information contact Lumina Power Inc 26 Ward Hill Ave Bradford MA 01835 Ph 978 241 8260 Fx 978 241 8262 Email sales luminapower com Web site www luminapower com ...

Reviews: