Important guidelines for mounting and use of 
sight glass fittings, toughened glasses and luminaires:

Before installation and operation/servicing, please read and follow all commissioning and servicing instructions.

1. 

Installation of sight glass fittings

 

The installation by welding, brazing etc, must be free of distortion 
and thus carried out by suitably qualified and authorized personnel.

2. 

Installing toughened glass discs into a sight glass assembly

2.1  Operating safety of sight glasses depends to a great extent upon their 

correct installation.

2.2  The gasket seating surfaces in the flanges must be plane, flat and 

smooth. Ensure the gasket edges are not trapped by, or foul, the 

 

flange gasket recess wall.

2.3  The glass disc, with gaskets appropriate to the process application 
 

fitted to its top and bottom faces must be located concentrically in 
the flange assembly.

2.4  Only use gaskets which are in good condition, flat and free of dirt 

and grease.

2.5  Before tightening nuts or bolts ensure once more that cover and base 

flanges are correctly aligned and surfaces parallel to one another.

2.6  Tighten the nuts or bolts progressively in diametrically opposed pairs. 

Tightening moments can be obtained from the relevant data sheets 
accompanying product (or consult supplier).

2.7  Further tightening down may be required after assembly has bedded 

down under operating temperature and pressure.

2.8  When installing quartz sight glass discs follow manufacturers’ 
 

instructions!

3. 

Max. loading of toughened sight glass discs

3.1  Correctly fitted sight glass discs must be used within the working 
 

temperature and pressure ranges laid down for them otherwise they 
may fail.

3.2  Temperature cycling to be within permitted limits:
 

• Sodalime glass (DIN 8902), max permissible temperature: +150° C.

 

  Temperature change within one minute max from 120° C to 20° C    
  with glass fully immersed.

 

• Borosilicate glass (DIN 7080), max permissible temp.: + 280° C.

 

  Temperature change within one minute max from 230° C to 20° C    
  with glass fully immersed.

3.3  Avoid spraying sight glasses which are still hot with cold fluid. 
 

Warning! This can lead to glass disc breakage.

3.4  Safety Precautions when using sight glass discs: 
3.4.1 Scheduled Maintenance:
 

Sight glasses must be included in preventive maintenance, and 

 

regularly checked either visually or by ultra sound measurement of 
wall thickness. Where a disc shows any damage it must be exchanged 
promptly with the plant shut down. Further, a thorough and regular 
check of the sight glass should lead to a down time to suit the 

 

par ticular vessel; this will promote a routine for glass exchange suited 
to the process.

3.4.2 Breakage of glass disc:
 

In spite of careful fitting and operation in accordance with instruc-
tions, it is possible though rare, that due to external effects a glass 
disc can fail. It is necessary, particularly in the case of critical processes 
such as in the food industry, that the plant manufacturer or operator 
takes appropriate safety measures to prevent glass fragments finding 
their way into the product.

3.5  After dismantling a sight glass assembly, and in accordance with 
 

DIN 7080 standard requirements for all type of sight glass disc, the 
glass disc and gaskets are replaced with new ones before the 

 

assembly is put back into operation. This is particularly important 
where pressure vessels and/or aggressive media are concerned.

 

The following wording as extracted from DIN 7080 refers: 

        “Sight glass discs may only be installed by personnel who are 
 

thoroughly versed about the following requirements:

 

• careful treatment of sight glass discs

 

• cleaning of recesses, discs, gaskets and accessories prior to installa-    
  tion, i. e. the removal of foreign matter (e. g. machining swarf);

 

• even tightening up of holding down bolts.

 

Sight glass discs removed from assemblies following operational 

 

service may not be reused.”

4. 

Sight glass wiper

4.1  Check that wiper assembly is correctly installed (see separate 
 

installa tion instruction)!

4.2  Wipers may only be used within temperature and pressure ranges 
 

specified.

4.3  Drive/spindle housing should be periodically checked to ensure a good 

seal; if necessary tighten threaded bushes/glands, replace defective 
seals, clean wiper arms and blades to remove accumulated foreign 
matter or replace (see installation instruction).

5. 

Spray device

 

The spray fluid temperature should be as near as possible to that of 
vessel contents. On no account use cold spray fluid on hot glass disc 
(see ‚temperature cycling‘ under point 3).

6. 

Sight glass luminaires

6.1  Always ensure that luminaire is connected to correct supply voltage as 

indicated on identity plate.

6.2  All luminaires are purpose designed and exclusively made for moun-

ting onto flanged sight glass assemblies.

6.3  Never use the luminaire in place of cover flange or a complete sight 

glass fitting.

6.4  Only certain models of luminaire may be used in con tinuous ON 

mode; please check before confirming order; if in doubt ask supplier 
or manufacturer.

6.5  Luminaires with built in ‚non maintained‘ switches are for intermit-

tent use and may only be operated with those switches.

6.6  Luminaires intended by the user for continuous ‚ON‘ mode operation 

should be controlled by separate external ON/OFF switch.

6.7  The following should also be noted
 

• Max. permissible temperature at cable entry not to be exceeded 

 

  (see data sheet).

 

• Max. permissible temperature of glass not to be ex ceeded (Vessel    
  tempe temperature increase caused by luminaire = 

 

  sight glass temperature; check by measurement!) 

6.8.  When replacing lamps use identical type with identical power rating; 

never exceed max. permissible lamp rating recommended for any 
given luminaire. 

6.9  When changing lamps, check condition of lamp socket as a matter 
 

of course.

6.10  Excessive voltage will shorten lamp life.

7. 

Ex Hazardous areas

 

Ex hazard rated luminaires must not be installed or serviced other 
than by suitably qualified and authorised personnel. Data and 

 

instructions contained in relevant approval test certificates (certifi-
cates of conformity) must be adhered to. Some Ex luminaire models 
are works fitted with permanently encapsulated (resin cast) cable 
tails; on no account attempt to unscrew or remove cable entry gland! 
Any inappropriate change in components of Ex certified luminaires 
can render the relevant certificate invalid.

 8.  Hinged or screwed sight glass assemblies

  

Before use, ensure the seals are functioning (if necessary tighten 

 

securing nuts/bolts).

 

The seal between hinged ports and vessel flange is en sured by 

 

correctly seated components; flanges to mate up parallel by correctly 
adjusted swing-bolt/hinge assembly and undamaged, clean seals free 
of grease.

 

In the case of hinged units, ensure the material of the hinged glass 
serround is compatible with vessel contents. When used on pressure 
vessels, ensure max. operating pressure specified for the sight glass is 
exceeded.

If in doubt, consult supplier or manufacturer!

Sales:  Malux Finland Oy, P.O.Box 69, FI-06151 Porvoo, Phone +358 19 574 5700, Fax +358 19 574 5750, [email protected]