WARNING
–
Risk of Electric Shock:
•
Install in accordance with all local codes and ordinances.
•
A fixture shall not use tungsten halogen lamps unless the luminaire is marked for such lamps.
IMPORTANT
TRANSFORMER
•
Install in accordance with all local codes and ordinances.
•
Only use a UL1838 transformer for safety reasons and to ensure full lifespan of the fixture.
•
Ensure that the transformer is plugged in to a GFCI protected circuit.
FIXTURE
DO NOT EXCEED 15 VOLTS INPUT
•
Install in accordance with all local codes and ordinances.
•
This fixture functions best when the incoming voltage is between 10
–
15 volts. Voltages outside of this range
could damage the fixture, shorten the life, and cause unsatisfactory performance. The use of improper voltage
voids the product warranty.
LOW VOLTAGE CABLE
•
Install in accordance with all local codes and ordinances.
•
Be protected by routing near the luminaire, or next to a building structure such as a house or deck.
•
Not be buried except for a maximum of 6 inches (15.2 cm) to connect to the main low voltage cable.
•
Have the length cut off so that it is connected to a connector within
6 inches (15.2 cm) from a building structure,
a luminaire, or fitting.
It is
not recommended
to
use Quick Clip style connectors because they are not waterproof and can rot creating resistance
and shorts. Only use outdoor rated waterproof wire connectors. Install in accordance with all local codes and ordinances.
LED LIFE
• For maximum light outp
ut, adjust lighting circuits to provide between 10-15 volts.
• Voltage can be regulated by adjusting circuit load/run.
• To determine circuit voltage, use a digital voltmeter at the fixture.