19
Rated operating frequency: 40 to 400 Hz
Power input : < 2 W resp. < 4.0VA
Basic accuracy :
Limit error < ± 0.2%
Including linearity and
reproducibility errors
Rated operating Voltage: 60 to 300
V
a.c.
/
d.c.
Ambient temperature
0
23 C + 2 C
0
Output burden
Current: 0.5*R max.
ext
Temperature
< + 0.15% per 10 C
0
< + 0.1%
Longtime drift
< + 0.3%/ 12 months
Switch- on drift
< + 0.2%
Mechanical
Lexan 940 (polycarbonate)
Housing
Flammability Class V-0 acc. To UL
94 self extinguishing, non dripping,
free of halogen.
Mounting position
Rail mounting / wall mounting
Weight
Approx. 0.2 kg
20 to 40 V
a.c.
/
20 to 60 V
d.c.