Remarks concerning the operator safety:

1. General

n

 The digital clock is destined to be installed inside or outside buildings.

n

 Non-authorized removal of the required housing, inappropriate use, incorrect installation or opera-

tion create the risk of injury to personnel or damage to equipment. For more detailed information 
please study the user’s manual.

n

 All operations concerning transport, installation, and commissioning as well as maintenance must be 

carried out by qualified, skilled personnel and national regulations for the prevention of accidents 
must be observed.

n

 According to this basic safety information, qualified, skilled personnel are persons who are familiar 

with the installation, assembly, commissioning, and operation of the product and who have qualifi-
cations necessary for their occupation.

2. Transport, storage

Please observe the notes on transport, storage and appropriate handling.
Observe the climatic conditions given in Technical Data.

3. Installation

n

 The DZ digital clock must be installed according to the regulation and instructions given in this user’s 

manual.

n

 Ensure proper handling and avoid mechanical stress.

n

 Do not bend any components and do not change any insulation distances.

n

 Do not touch any electronic components and contacts.

n

 Electronic devices may contain electrostatically sensitive components, which can easily be dama-

ged by inappropriate handling.

n

 Do not damage or destroy any electrical components since this might endanger your health!

4. Electrical connection

n

 Before switching the digital clock on, one must check the correctness of connection to the network.

n

 In case of the protection terminal connection with a separate lead one must remember to connect it 

before the connection of the digital clock to the mains.

n

 When working on live instruments or devices, the applicable national regulations for the prevention 

of accidents must be observed.

n

 The electrical installation must be carried out according to the appropriate regulations (cable cross-

sections, fuses, PE connection). Additional information can be obtained from the user’s manual.

n

 Do not connect the digital clock to the mains via an autotransformer.

n

 The documentation contains information about installation in compliance with EMC (shielding, groun-

ding, filters and cables). These notes must be observed for all CE-marked products.

n

 The manufacturer of the installation or installed auxiliary devices is responsible for the compliance 

with the required limit values demanded by the EMC legislation.

n

 The 

RS-485 socket

 serves only for the connection of digital clocks operating with the MODBUS 

protocol.

5. Operation

n

 Installations including DZ2 or DZ3 digital clocks must be equipped with protection devices accor-

ding to the corresponding standard and regulations for prevention of accidents.

n

 After the digital clock has been disconnected from the supply voltage, live components and power 

connections must not be touched immediately because capacitors can be charged.

n

 The housing must be closed during operation. 

Summary of Contents for DZ2

Page 1: ... USER S MANUAL LARGE SIZE DIGITAL CLOCKS DZ2 AND DZ3 TYPES ...

Page 2: ... ...

Page 3: ...3 BASIC REQUIREMENTS OPERATIONAL SAFETY 5 4 DESIGN AND INSTALLATION 7 5 WIRING CONNECTIONS 8 6 REGISTER MAP OF THE CLOCK CONTROLLER 9 7 TECHNICAL DATA 11 8 ORDERING CODES 12 9 BEFORE A FAILURE WILL BE DECLARED 13 10 MAINTENANCE AND WARRANTY 13 ...

Page 4: ... ...

Page 5: ...ime standard The luminosity of digits is programmed by the user taking into consideration the night time 2 CLOCK SET The set consists of digital clock 1 pc user s manual 1 pc warranty card 1 pc female connector on the cable 2 pcs DCF receiver with the cable 1 pc When unpacking the watt hour meter please check the delivery completeness and whether the type and version code on the data plate corresp...

Page 6: ...estroy any electrical components since this might endanger your health 4 Electrical connection n Before switching the digital clock on one must check the correctness of connection to the network n In case of the protection terminal connection with a separate lead one must remember to connect it before the connection of the digital clock to the mains n When working on live instruments or devices th...

Page 7: ...using dimensions DZ2 1510 284 77 mm DZ3 2020 360 77 mm The DCF receiver is fixed separately and should be distant from electromagnetic field sources current carrying wires big metallic objects and electronic devices If it is possible the receiver should be situated outside the building The DCF signal is broadcasted from Germany in the shape of 0 1 sec and 0 2 sec pulses in one second intervals If ...

Page 8: ...d layout of holes and suspension clamps 5 WIRING CONNECTIONS The clock set includes two female cable connectors a 3 pole supplying connector and a 4 pole inter face connector The DCF receiver is delivered with a plug One must perform electrical connectors acc to the Fig 3 Fig 3 Electrical connections ...

Page 9: ...plemented in the controller Applied markings R readout W writing DZ configuration registers registers 4000 4037 All configuration registers are 16 bit registers of unsigned integer type Register address operations Range Description 4000 RW 1 247 DZx clock type address in MODBUS network 4001 RW 0 3 Operating mode of the interface no 1 0 RTU 8N1 1 RTU 8N2 2 RTU 8E1 3 RTU 8O1 4002 RW 0 9 Baud rate of...

Page 10: ...gister then a logic product will be performed on the register value with the written value The meaning of bits is as follows Bit 15 Error of RAM memory Bit 14 erroneous settings Factory settings were restored Bit 13 Setting error of RTC clock or lack of the correct DCF frame The flag is automatically erased in case of a correct DCF frame Bit 12 A change of summer winter time has occured or inverse...

Page 11: ...P 54 Dimensions DZ2 width 1510 mm height 285 mm depth 77 mm DZ3 width 2020 mm height 360 mm depth 77 mm Reference conditions and rating operating conditions operating temperature 10 23 55 C storage temperature 20 80 C humidity 25 95 supply 85 253 V external magnetic field 0 40 400 A m operating position any heating time 1 minute Standards fulfilled by the digital clock Electromagnetic compatibilit...

Page 12: ...ith digits of 200 mm high R digit colour on display red 00 standard version DIGITAL CLOCK DZ X X XX Digit height 200 mm 2 300 mm 3 Digit colour on the display field red R yellow Y green G Version standard 00 custom made XX the code number will be established by the manufacturer ...

Page 13: ...iod of 12 months since the date of purchase One should take the digital clock down from the installation and return it to the Manufacturer Quality Control Dept If the unit has been used in compliance with the instructions the Manufacturer warrants to repair it free of charge 2 After the warranty period One should turn over the digital clock meter to repair it in a certified service workshop The di...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...LAMP ON METERS INDUSTRIAL PROCESS and POWER CONTROLLERS CHART and PAPERLESS RECORDERS LARGE SIZE DISPLAY PANELS ELEMENTS OF INTEGRATION SYSTEMS ACCESSORIES FOR MEASURING INSTRUMENTS SHUNTS MEASURING SYSTEMS ENERGY HEAT CONTROL CUSTOM MADE PRODUCTS WE ALSO OFFER OUR SERVICES IN THE PRODUCTION OF ALUMINIUM ALLOY PRESSURE CASTINGS PRECISION ENGINEERING and THERMOPLASTIC PARTS SUBCONTRACTING of ELECTR...