background image

7 Reference Numbers

7.1 Reference numbers instrument

Type

Temperature 

Range 

Reference 

Number

IS 6-TV Advanced

(PAL / RS485)

600 to 1800 °C (MB 18)

3 914 570

600 to 3000 °C (MB 30)

3 914 530

IGA 6-TV Advanced

(PAL / RS485)

250 to 1800 °C (MB 18)

3 914 070

250 to 2500 °C (MB 25)

3 914 030

IGA 6/23-TV Advanced

(PAL / RS485)

50 to 1000 °C (MB 10)

3 914 230

75 to 1300 °C (MB 13)

3 914 270

150 to 1800 °C (MB 18)

3 914 310

ISR 6-TV Advanced

(PAL / RS485)

600 to 1400 °C (MB 14)

3 904 030

700 to 1800 °C (MB 18)

3 904 090

800 to 2500 °C (MB 25)

3 904 160

1000 to 3000 °C (MB 30)

3 904 230

IGAR 6-TV Advanced

(PAL / RS495)

100 to 2000 °C (MB 20)

3 914 720

Ordering note:

Connection and video cables are not included in scope of delivery and must be

ordered separately.

7.2 Reference numbers accessories (video related)

3 920 600

3 920 610
3 920 620

3 920 630

3 920 640

3 920 650

3 920 660
3 920 670

3 920 680

3 920 690

Video cable BNC, 5 m long

Video cable BNC, 10 m long
Video cable BNC, 15 m long

Video cable BNC, 20 m long

Video cable BNC, 25 m long

Video cable BNC, 30 m long

Video cable BNC, 40 m long
Video cable BNC, 45 m long

Video cable BNC, 60 m long

Video cable BNC, 100 m long

All video cables include an

adapter BNC-socket to RCA

male (CINCH)

3 826 740 

Passive Video Baluns with BNC connectors for transmitting video signals over

standard inexpensive patch cable (eg CAT5 cable). Maximum cable length:
300 m with color video.

3 826 730 

Video grabber (converts analog TV to USB)

上海麦兴 版权所有

!

!

!

麦兴(中国)有限公司

地址:香港湾仔告士打道151号国卫中心11楼

电话:
传真:

邮箱:

(852) 2836 8361

(852) 3011 5863

[email protected]

w w w . i m a x s u n . c o m

上海麦兴仪器设备有限公司

地址:上海市浦东新区张杨路188号汤臣中心A座

电话:

传真:

邮箱:

邮编:

(86 21) 5888 7876

[email protected]

MaxSun (China) Limited.

(86 21) 5888 6718 / 133 8186 8102

200122

Shanghai MaxSun Industrial Co., Ltd.

Summary of Contents for IGA 6-TV Advanced

Page 1: ...meters IS 6 TV Advanced IGA 6 TV Advanced IGA 6 23 TV Advanced ISR 6 TV Advanced IGAR 6 TV Advanced Addendum to IS 6 Advanced IGA 6 Advanced IGA 6 23 Advanced ISR 6 Advanced and IGAR 6 Advanced Manual...

Page 2: ...sions 10 3 Electrical Installation 11 3 1 Video Output Electrical Connection 11 3 1 1 Video Image 11 Operating Mode 12 4 Software InfraWin 13 4 1 Set Video Mode Parameters 13 4 2 Adjusting Brightness...

Page 3: ...included Video signal can be switched off via software Operating ambient temperature 0 to 60 C on the housing Note During operation the instruments will warm up and might reach an intrinsic temperatur...

Page 4: ...Series 6 TV Advanced Manual Electrical Installation 10 2 2 Dimensions All dimensions in mm...

Page 5: ...is used for aligning the pyrometer to the measuring object and shows the following information The measuring object and its surroundings Target marking circle The size of the circle corresponds to th...

Page 6: ...only 2 channel mode 2 dots displayed If the signal falls below the set Relative Signal see Relative Signal in ISR 6 Advanced or IGAR 6 Advanced Manual the temperature displayed on the image will be fl...

Page 7: ...isplay in addition to measuring temperature o Off no parameter is displayed o Device temperature o Measuring distance o Serial number o Signal intensity ISR 6 TV Advanced and IGAR 6 TV Advanced only B...

Page 8: ...ss can be set where the automatic control should work With the yellow button the selected range can be moved If the circle representing the current brightness is within the chosen range automatic brig...

Page 9: ...rawin 15 Comparison between manual and automatic control of brightness The measuring temperature was changed for the image recording from the beginning of the measuring range to 1200 C Manual brightne...

Page 10: ...be size adjusted and positioned at any place of the screen The properties of the pyro s video chip as well as properties of the video grabber can be adjusted with InfraWin 5 5 1 1 Adjusting Grabber S...

Page 11: ...rently only PAL_B is supported 5 1 3 Viewing the Video Image During a temperature measurement of the pyrometer the video image can be displayed on the screen by pressing the TV button The video image...

Page 12: ...th the 2 digit device address AA e g 00 This is followed by 1 lower case command letter and 2 numbers finished with CR Example Read Command Entry 00v08 CR Selectable parameter that is additionally sho...

Page 13: ...of 2 v01 Coordinates of temperature display read limits Answer 000300000208 PAL Format xxxXXXyyyYYY xxx min X Value XXX max X Value yyy min Y Value YYY max Y Value v02 description see v01 but Coordina...

Page 14: ...n see v10 however Text properties Overlay_3 v14 v14 store v10 v11 v12 v13 text properties in flash memory v18 v18 Brightness control settings read Answer 1 digit hex v18X Brightness control settings w...

Page 15: ...ontrol limits v24 Control limit read limits Answer 00FF00FF v25 v25 Control limit store selection in flash memory v26 v26 Time read Answer 6 digit decimal v26hhmmss Time write hh hour 00 23 mm minute...

Page 16: ...separately 7 2 Reference numbers accessories video related 3 920 600 3 920 610 3 920 620 3 920 630 3 920 640 3 920 650 3 920 660 3 920 670 3 920 680 3 920 690 Video cable BNC 5 m long Video cable BNC...

Reviews: