INSTALLATION INSTRUCTIONS
IN0174 17511
www.lumascape.com.au
Lumascape
Brisbane Technology Park
18 Brandl Street, Eight Mile Plains, QLD 4113, Australia
T
+61 7 3854 5000
F
+61 7 3854 5001
E
W
www.lumascape.com.au
LABEL
Wiring Details
CE Color Code
UL / ETL Color Code
Designation
Green / Yellow
Green
Earth / Ground
Brown
Black
Active / Live
Blue
White
Neutral
Black
Grey
Data *
* Data wire must be appropriately insulated if not connected.
Operating voltage on this wire is 24 V. Incorrect wiring will
damage luminaire and void warranty. Do not Hi-Pot test.
L
N
Bootlace ferrules must be ued on all wires
when connecting in terminal blocks.
DANGER
ISOLATE LUMINAIRE FROM POWER
Failure to isolate power
supply before installation or
maintenance may result in
fire, serious injury, electric
shock, death and may
damage the luminaire.
Connecting the luminaire
incorrectly can lead to permanent
damage and void warranty.
WARNING
FACADE LIGHT
LS9160
|
LS9180
Facade Luminaire
Warranty void if not installed as per installation instructions
MODEL
LS9160 | LS9180
INSTALLATION TYPE
Surface Mount
IP RATING
IP66
SUPPLY VOLTAGE
110-240 V AC, 50/60 H
INSTRUCTIONS COVER
Single Colour
Single Colour Dim
RGBx
Tunable White
NO POWER
TOOLS
DO NOT USE SILICONE
ON OUTSIDE SURFACE
KEEP ELECTRONICS FREE
FROM DIRT AND MOISTURE
DO NOT HOSE OR
PREASSURE CLEAN
N653
Luminaire Cable
Connect to a suitable power
supply in accordance with
local wiring rules.
Mounting Bracket
Use to attach luminaire to
suitable mounting surface.
Locking Screw
Use Allen key to lock luminaire
tilt into place after adjusting.
Washer Plate (Q6 Luminaire Only)
Use washer plate when attaching the mounting bracket to an accessory
or when mounting to any mounting surface using a countersunk screw.