Step 5
Step 6
Adjust luminaire tilt and tighten screw to lock in tilt.
Connect Luminaire to suitable 30 V DC power supply or low voltage PowerSync
™
master.
Ensure electrical connection is in accordance with local electrical code.
Power up the circuit to test the installation.
Tilt Adjustment
Tighten screw to lock
luminaire tilt into place.
Wiring Diagram
Wire Colour
Designation
Black
Power –
Red
Power +
Orange*
Data +
Grey*
Data –
* Do not connect if not required
Data Signal Wires
Incorrect wiring will damage
luminaire and void warranty.
Do not Hi-Pot test. Isolate
these conductors if data
injector is not in use.
QUESTIONS
Contact us at details below.