LS5030
INSTALLATION INSTRUCTIONS
UNDERWATER LUMINAIRE
SURFACE MOUNT
LUMASCAPE ASIA PACIFIC
Brisbane Technology Park, 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia
Phone +61 7 3854 5000 | Fax +61 7 3854 5001 | Email: [email protected] |
www.lumacape.com
LUMASCAPE NORTH AMERICA
1300 Industrial Road, Unit #19, San Carlos, CA 94070, USA
Phone +1 650 595 5862 | Fax +1 650 595 5820 | Email: [email protected] |
www.lumacape.com
Products and specifications are subject to change without notice.
USA I Australia I Asia I Middle East I Europe
4 / 4
IN0191US N180207
Step 5
Step 6
Adjust luminaire tilt and tighten screw to lock in tilt.
Connect Luminaire to suitable 30 V DC power supply or low voltage PowerSync
™
master.
Ensure electrical connection is in accordance with local electrical code.
Power up the circuit to test the installation.
Tilt Adjustment
Tighten screw to lock
luminaire tilt into place.
Wiring Diagram
Wire Colour
Designation
Black
Power –
Red
Power +
Orange*
Data +
Grey*
Data –
* Do not connect if not required
Data Signal Wires
Incorrect wiring will damage
luminaire and void warranty.
Do not Hi-Pot test. Isolate
these conductors if data
injector is not in use.
QUESTIONS
Contact us at details below.