INSTALLATION INSTRUCTIONS

Lumascape Lighting Industries Pty Ltd

38-44 Enterprise Street, Cleveland, QLD 4163, Australia

PO Box 1875, Cleveland D.C., QLD 4163, Australia

  07 3286 2299

F

   07 3286 6599

E

   [email protected]

W

 www.lumascape.com.au 

IN0098 - 28 August 2015

Copyright ©2015 Lumascape Lighting Industries Pty. Ltd.   ABN 21 010 572 773

www.lumascape.com.au

120 mm

6 mm

cable strip length

2.5 mm² max per terminal

WARNINGS 

Luminaires can become very hot. Use 

discretion in placement

Luminaires optical assembly is factory sealed 

and opening will void warranty

All connections must be kept dry; failure to 

do so may result in product reliability issues

Do not allow soil, mulch or foreign material 

to build up around the luminaire

Ensure installation complies with local 

regulations

Run cable(s) to luminaire:

 

Run a power supply cable and if necesary 
a CAT5 data cable (required for RGB 
& dimming) to the luminaire, ensuring 
compliance with local wiring rules.

1.

Punch gland holes:

 

Depending on your requirements punch 
out one or two holes and install gland(s) as 
shown in illustration on right.

2.

Water proof cable entry using gland:

 

Feed the cable through the gland and tighten 
as shown in illustration. Repeat this process 
if a secod gland is installed. Ensure a correct 
sized cable is used or seal will not be IP67. 

3.

Terminate electrical connection:

 

Strip and connect the cable cores to the terminal block as shown in the illustration. Ensure correct 
polarity is observed for the low voltage (24 V DC) luminaire.
For details on CAT5 data connection (required for RGB and dimming) refer to diagram in back.

4.

Mains Voltage Wiring

Low Voltage Wiring

-     +

Black

Green

White

Black

Red

Before you begin always check 
luminaire label for correct supply 
details and lamp type if applicable.

Refer to wiring 
diagram and dip 
switch settings in 
back for details.

COMPONENTS

x4

screw

gland

x2

x1

Allen key

x1

x1

gasket seal

concrete

anchor

Use only a single, circular cable 
with a diameter of 6-10 mm in 
gland to ensure a watertight seal.

DANGER

ISOLATE LUMINAIRE FROM POWER

Failure to isolate power 

supply before installation or 

maintenance may result in 

fire, serious injury, electric 

shock, death and may 

damage the luminaire.

SPOTLIGHT & FLOODLIGHT

LS422LED 

Centria Concrete Anchor 

Warranty void if not installed as per installation instructions

t 90 ºC

  

N653

MODEL

LS422LED

INSTALLATION TYPE

Concrete Anchor

IP RATING

IP66 / IP67

SUPPLY VOLTAGE

100-240 V AC, 50/60 Hz
24 V DC

INSTRUCTIONS COVER

Single Colour
Single Colour Dimming 
RGB (Integral Driver)

NO POWER 

TOOLS

KEEP AWAY FROM

FLAMMABLE MATERIAL

DO NOT USE SILICONE

ON OUTSIDE SURFACE

KEEP ELECTRONICS FREE 

FROM DIRT AND MOISTURE

DO NOT HOSE OR

PREASSURE CLEAN