INSTALLATION INSTRUCTIONS
Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
PO Box 1875, Cleveland D.C., QLD 4163, Australia
T
07 3286 2299
F
07 3286 6599
E
W
www.lumascape.com.au
IN0098 - 28 August 2015
Copyright ©2015 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
www.lumascape.com.au
120 mm
6 mm
cable strip length
2.5 mm² max per terminal
WARNINGS
Luminaires can become very hot. Use
discretion in placement
Luminaires optical assembly is factory sealed
and opening will void warranty
All connections must be kept dry; failure to
do so may result in product reliability issues
Do not allow soil, mulch or foreign material
to build up around the luminaire
Ensure installation complies with local
regulations
Run cable(s) to luminaire:
Run a power supply cable and if necesary
a CAT5 data cable (required for RGB
& dimming) to the luminaire, ensuring
compliance with local wiring rules.
1.
Punch gland holes:
Depending on your requirements punch
out one or two holes and install gland(s) as
shown in illustration on right.
2.
Water proof cable entry using gland:
Feed the cable through the gland and tighten
as shown in illustration. Repeat this process
if a secod gland is installed. Ensure a correct
sized cable is used or seal will not be IP67.
3.
Terminate electrical connection:
Strip and connect the cable cores to the terminal block as shown in the illustration. Ensure correct
polarity is observed for the low voltage (24 V DC) luminaire.
For details on CAT5 data connection (required for RGB and dimming) refer to diagram in back.
4.
Mains Voltage Wiring
Low Voltage Wiring
- +
Black
Green
White
Black
Red
Before you begin always check
luminaire label for correct supply
details and lamp type if applicable.
Refer to wiring
diagram and dip
switch settings in
back for details.
COMPONENTS
x4
screw
gland
x2
x1
Allen key
x1
x1
gasket seal
concrete
anchor
Use only a single, circular cable
with a diameter of 6-10 mm in
gland to ensure a watertight seal.
DANGER
ISOLATE LUMINAIRE FROM POWER
Failure to isolate power
supply before installation or
maintenance may result in
fire, serious injury, electric
shock, death and may
damage the luminaire.
SPOTLIGHT & FLOODLIGHT
LS422LED
Centria Concrete Anchor
Warranty void if not installed as per installation instructions
t 90 ºC
N653
MODEL
LS422LED
INSTALLATION TYPE
Concrete Anchor
IP RATING
IP66 / IP67
SUPPLY VOLTAGE
100-240 V AC, 50/60 Hz
24 V DC
INSTRUCTIONS COVER
Single Colour
Single Colour Dimming
RGB (Integral Driver)
NO POWER
TOOLS
KEEP AWAY FROM
FLAMMABLE MATERIAL
DO NOT USE SILICONE
ON OUTSIDE SURFACE
KEEP ELECTRONICS FREE
FROM DIRT AND MOISTURE
DO NOT HOSE OR
PREASSURE CLEAN