Lumascape LS411LED Installation Instructions Manual Download Page 1

INSTALLATION INSTRUCTIONS

Lumascape Lighting Industries Pty Ltd

38-44 Enterprise Street, Cleveland, QLD 4163, Australia

PO Box 1875, Cleveland D.C., QLD 4163, Australia

  07 3286 2299

F

   07 3286 6599

E

   [email protected]

W

  www.lumascape.com.au 

IN0025 - 6 August 2014

Copyright ©2014 Lumascape Lighting Industries Pty. Ltd.   ABN 21 010 572 773

www.lumascape.com.au

DANGER

ISOLATE LUMINAIRE FROM POWER

Failure to isolate power 

supply before installation or 

maintenance may result in 

fire, serious injury, electric 

shock, death and may 

damage the luminaire.

Luminaire can become very hot. 

Use discretion in placement.

Ensure that installation complies 

with local authority standards.

All connections must be kept 

dry; failure to do so may result 

in product reliability issues.

Screw seals and sleeve must be 

fitted or warranty void.

WARNING

LS6023 

(ordered separately)

LS411 

Surface Mount 

Base

LS411 

Adaptor Base

LS6025

(ordered separately)

OR

OR

LS411 

Concrete Anchor / 

Spike

Select Mounting Option

See individual mounting accessory 
instructions overleaf

1.

Power supply must be 

isolated prior to connection 

or disconnection of cables. 

2.

Terminate luminaire. Single colour, non-dimmable, mains-voltage 
version depicted in example. Refer to wiring diagrams below 
for details. Earth lug connection only required for mains voltage 
version of luminaire.

Select the grommet to suit wiring conductors. For correct cable selection refer 
to table on top right. Screw mounting base to mounting accessory or screw 
directly to mounting surface using 4 screws provided (holes for mounting 
screws may be supplied blind. Drill through as required with a 4.5 mm drill. A 
screw must be used for each hole drilled to achieve IP67 rating.)

Surface Mount Base

IMPORTANT

  For All Mounting Options

Select a suitable power supply and locate centrally in relation to desired luminaire locations. 
Use discretion in placement as luminaire can become very hot and may burn. Run conduit 
and drill / cast holes as specified. Run cables. Maximum distance for remote drivers is 30 m 
from the luminaire. Use table on right to select a suitable supply cable with the appropriate 
number of conductors for the luminaire you are installing.

Luminaire Type

No. of supply cores needed

Single colour, low-voltage, non-dimmable

2

Single colour, low-voltage, dimmable

4

Single colour, mains-voltage, non-dimmable

3

Integral RGB driver

6

Remote RGB driver

6

E

Earth lug only required 
for mains voltage

NOTE: Use only 1 x circular 
cable to keep IP rating

SPOTLIGHT & FLOODLIGHT

LS411LED

 Omnio Mini

Warranty void if not installed as per installation instructions

  

N653

MODEL

LS411LED

INSTALLATION TyPE

Surface Mount Base
Pole Clamp (LS6023)
Signage System (LS6025)
Concrete Anchor / Spike

IP RATING

IP67

SUPPLy VOLTAGE

100-240 V AC, 50/60 Hz
24 V DC Ripple Free Supply
12 V AC Magnetic Transformer

INSTRUCTIONS COVER

Single Colour
Single Colour Dimming
RGB (Integral & Remote Driver)

NO POWER 

TOOLS

KEEP AWAY FROM

FLAMMABLE MATERIAL

DO NOT USE SILICONE

ON OUTSIDE SURFACE

KEEP ELECTRONICS FREE 

FROM DIRT AND MOISTURE

DO NOT HOSE OR

PREASSURE CLEAN

see over for wiring diagrams

Summary of Contents for LS411LED

Page 1: ... base to mounting accessory or screw directly to mounting surface using 4 screws provided holes for mounting screws may be supplied blind Drill through as required with a 4 5 mm drill A screw must be used for each hole drilled to achieve IP67 rating Surface Mount Base IMPORTANT For All Mounting Options Select a suitable power supply and locate centrally in relation to desired luminaire locations U...

Page 2: ... Wiring Diagrams Low Voltage Mains Voltage RGB Remote Driver Wire Colour Designation Red Red Orange Red Green Green White Green Blue Blue Black Blue RGB Integral Driver Wire Colour Designation AC DC White 1 AC1 White 2 AC2 Orange PWM Common Red PWM Red Green PWM Green Blue PWM Blue Single Colour Dimming Wire Colour Designation AC DC White 1 AC1 White 2 AC2 Orange PWM Red Green PWM Blue Single Colo...

Page 3: ... depicted in example Refer to wiring diagrams below for details Aim luminaire Refer to Surface Mount Base section for lamping instructions NOTE Use only 1 x circular cable to keep IP rating Wiring Diagrams Low Voltage Mains Voltage RGB Remote Driver Wire Colour Designation Red Red Orange Red Green Green White Green Blue Blue Black Blue RGB Integral Driver Wire Colour Designation AC DC White 1 AC1 ...

Page 4: ...ll need to exit the mounting surface into the hollow of the signage pole 2 Use discretion in placement as luminaire can become very hot and may burn 3 Select purchase appropriate stainless steel fasteners for mounting substrate Not supplied 1 Feed supply cable through pole until exiting mounting stud at the end 2 Bolt signage pole to wall 3 Open turnbuckle to approximately half of it s adjustment ...

Page 5: ...ircular cable to keep IP rating Wiring Diagrams Low Voltage Mains Voltage RGB Remote Driver Wire Colour Designation Red Red Orange Red Green Green White Green Blue Blue Black Blue RGB Integral Driver Wire Colour Designation AC DC White 1 AC1 White 2 AC2 Orange PWM Common Red PWM Red Green PWM Green Blue PWM Blue Single Colour Dimming Wire Colour Designation AC DC White 1 AC1 White 2 AC2 Orange PWM...

Page 6: ...ngle Colour NOTE For mains voltage use as concrete anchor only Contractor is to ensure installation complies with local wiring rules Tighten screw to secure luminaire to base Connect luminaire cable in accordence with local wiring rules See diagram below for details 4 Mains Voltage CONCRETE ANCHOR ONLY Finished surface level Conduit Concrete Correct installation Incorrect installation Void warrant...

Page 7: ...pose only 3 Do not operate the luminaires with a missing or damaged parts 4 Use only genuine Lumascape parts to replace damaged or missing components 5 Refer to instructions for installation and operating requirements 6 Ensure installation complies with local regulations Voltage insulation test megger will permanently damage product and will void warranty SAVE THESE INSTRUCTIONS SAFETY INSTRUCTION...