WARNING - To reduce the risk of FIRE or INJURY:

1.  Luminaires and transformers to be installed by licensed electrical contractors.
2.  Luminaires to be used for intended purpose only. 
3.  Do not operate the luminaires with a missing or damaged parts.
4.  Use only genuine Lumascape parts to replace damaged or missing components.
5.  Refer to instructions for installation and operating requirements.
6.  Ensure installation complies with local regulations

Voltage insulation test (megger) will permanently damage product and will void warranty.
SAVE THESE INSTRUCTIONS.

SAFETY INSTRUCTIONS

Questions?

Call +61 7 3286 2299

Email [email protected]

www.lumascape.com.au

NOTE: 24 V DC power supplies are far more efficient than AC transformers.

NOTE: 24 V DC power supplies are far more efficient than AC transformers.

 means the maximum number of luminaires can be accommodated on smaller cables.

 means the maximum number of luminaires can be accommodated on smaller cables.

LS333ANS-2LED (6W)
Power Supply/ Transformer & Maximum Cable Runs

6 W Luminaire

24 V DC Power Supply

12 V AC Magnetic Transformer

Wattage 
(Part Number)

100 W (LS100DC)

100 VA (LS100TX)

50 VA (LS50TX)

Lumascape Cable

LS604

LS604-6 LS604-10

LS604 LS604-6 LS604-10

LS604 LS604-6 LS604-10

Cable size

3.3 mm

2

6 mm

2

10 mm

2

3.3 mm

2

6 mm

2

10 mm

2

3.3 mm

2

6 mm

2

10 mm

2

No. of luminaires 

100 metre run

10

0

0

1

0

0

1

No. of luminaires 

75 metre run

10

0

1

0

1

No. of luminaires 

50 metre run

10

1

2

1

2

No. of luminaires 

25 metre run

10

2

3

5

2

3

5

LS333ANS-2LED (3W)
Power Supply/ Transformer & Maximum Cable Runs

3 W Luminaire

24 V DC Power Supply

12 V AC Magnetic Transformer

Wattage 
(Part Number)

100 W (LS100DC)

100 VA (LS100TX)

50 VA (LS50TX)

Lumascape Cable

LS604

LS604-6 LS604-10

LS604 LS604-6 LS604-10

LS604 LS604-6 LS604-10

Cable size

3.3 mm

2

6 mm

2

10 mm

2

3.3 mm

2

6 mm

2

10 mm

2

3.3 mm

2

6 mm

2

10 mm

2

No. of luminaires 

100 metre run

18

0

0

2

0

0

2

No. of luminaires 

75 metre run

18

0

2

2

0

2

2

No. of luminaires 

50 metre run

18

2

2

4

2

2

4

No. of luminaires 

25 metre run

18

3

5

9

3

5

9

POWER SUPPLY SIZES & CABLE RUN LENGTHS

NOTE: In Australia, each luminaire must be installed as detailed in AS3000 Clause 6.4.4.5