18
?
Query for the current status of inputs, built-in relays
and GSM signal strength
G7=ON or G7=OFF
Switching of Gecon7 or Gecon Lite Plus versions
IN1=1 IN2=0 ...
Current status of inputs (cannot be overwritten)
R=OFF R=ON
R=TROUBLE
Setting of built-in relay: off/on/trouble
RR=110
Output for auxiliary relay at terminal 5, 6 and 7.
1
– output on. If 5, 6 and 7 should be used as inputs,
they must be configured as RR=000
R5=ON … R7=OFF
Output for relay 5, 6 and 7 can be controlled
separately
SIG:87%
GSM signal strength (cannot be overwritten) %
WPRINT
Setting of the dictionary for online printing, every word
has 15 characters maximum
W1=ALARM# W2=...
Text message is sent based on a given keyword;
if the word begins with an asterisk
– cancellation,
sending cancelled
if the word begins with an exclamation point
– a call
will be made
BAUD=1200
Online printing 8N1 line speed;
supporting: 1200, 2400, 4800, 9600, 19200
HELP
Information on query commands HELP VER PHONE
TEXT WPRINT ?
AUDIO=REC
Activation of audio message recording mode for a
period of 30 minutes
AUDIO=ON
Activates the playing of audio messages in case of
alarm and disables the recording mode
AUDIO=OFF
Deactivates the playing of audio messages in case of
alarm and disables the recording mode
Signalling
Red LED1
5
flashing 1:1 unless the GSM is registered in operator network
6
short flashes - GSM registered in operator network
7
steady light when sending messages or input violation
Green LED2
off if G7=OFF
on if G7=ON
flashes once if the text message password is incorrect, twice if the
password is correct