GECON LITE PLUS
&
GECON - 7
INSTALLATION INSTRUCTIONS
Version 1, SW 15c
Page 1: ...GECON LITE PLUS GECON 7 INSTALLATION INSTRUCTIONS Version 1 SW 15c...
Page 2: ...the device do not expose the device to moisture water or direct heat sources Table of Contents Basic Information 3 Technical Specifications 3 Wiring Diagram 4 Installation 5 Device Setting 6 Current...
Page 3: ...inform about power failure heating etc Technical Specifications Number of inputs 4 3 unbalanced Operating input modes alarm status Number of outputs 1 relay 3 x programmable output open collector 200...
Page 4: ...4 Wiring Diagram...
Page 5: ...N On 1 Insert the SIM card into the communicator 2 Connect the communicator to voltage 3 Automatic registration to the GSM network is under way If the registration is not completed after 60 seconds se...
Page 6: ...ocation is elsewhere see the diagram 4 LED output is removed 5 Prefix in online printing for cancellation was changed from to Device Setting GSM gateway that allows different types of traffic it is th...
Page 7: ...of the number The abcd PHONE command returns phone number setting to SMS Setting phone number automatically sets the routing of events from all inputs to this number The routing of these messages can...
Page 8: ...puts set as abcd IN AATA It has 7 inputs set as abcd IN AATAATA Examples abcd IN AAAA All inputs are alarm abcd IN ATTT The first input is alarm the others are status fault Using the commands see p 11...
Page 9: ...utes input restoration is reported immediately D3 D4 Delay of inputs 1 to 7 D1 time delay of input 1 to the alarm or fault by time indicated in minutes input restoration is reported immediately D6 D7...
Page 10: ...xample abcd RE4 deleting message RE4 Using the commands see p 9 Practical Example Password Change The Login password can be changed and the change is recommended for safety reasons This password is se...
Page 11: ...t 5 6 or 7 Terminals 5 6 and 7 should not get higher voltage than the supply voltage It is therefore unacceptable that the relays would be powered from a source other than the powered GECON 7 Gecon7 G...
Page 12: ...sword Query commands must be placed at the end of text message Each command is separated by a space Example abcd T1 090xxxxxxx T2 090yyyyyyy VT2 1 IN ATTA LOG CCOO logic of inputs NC NO the first and...
Page 13: ...g the keyword off to SMS but if you set a cancellation command for the word 45 the text message will not be sent Configuration SMS abcd print on W1 off W2 code 45 As for the setting of routing these m...
Page 14: ...ine message 14 25 ALARM PIR hall 14 26 DISARM Smith Examples of practical use 1 Signalling the alarm with exact localization 2 Checking the arming disarming 3 Monitoring a particular person if they us...
Page 15: ...clicking Upload 8 If you want to save the settings use the Save button and save it to your computer drive Note The program uses automatic detection of a port which means it will find GECON itself ther...
Page 16: ...ia your mobile phone The number of the recorded message corresponds to the input number which the alarm message will be played for End each of the recorded messages by ending the call Repeat until you...
Page 17: ...nputs for G7 ON A alarm T tamper LOG OCCO LOG OCCOCOO Setting of input logic 4 inputs for G7 OFF 7 inputs for G7 ON O normally open C normally closed D1 2 D2 5 Setting of delay time min for 4 or 7 inp...
Page 18: ...rd if the word begins with an asterisk cancellation sending cancelled if the word begins with an exclamation point a call will be made BAUD 1200 Online printing 8N1 line speed supporting 1200 2400 480...
Page 19: ...e messages Steps 1 Disconnect GECON from power supply 2 Use RES jumper 3 Connect GECON power supply 4 Signalling LED 1 flashes 10 times and remains lit 5 Setting is reset 6 Disconnect the RES jumper 7...