background image

 

www.LumaComfort.com 

R

EPLACING THE 

F

ILTERS

 

The air purifier’s filters will need to be replaced periodically. When the filters 
need to be replaced, the filter indicator light will turn on. 

The life of the filters will depend on the amount of contaminants in the air and 
the frequency of use. As a general rule, the HEPA, VOC and TiO2 filters will last 
approximately 180-365 days while the carbon filter will last approximately 60-
90 days. Do not wash and reuse any of the filters. 

The HEPA filter in particular will need to be replaced when it turns brown. You 
will also notice that the air volume will dramatically decrease at this time. We 
recommend having a set of replacement filters on hand to ensure maximum 
performance. 

a.

 

Before replacing any of the filters, turn the air purifier off and unplug it 
from the power outlet. 

b.

 

Open the air purifier’s front grill by placing your hand on top of the air 
purifier’s cover, inserting your finger in the slot on the side of the unit and 
by pulling the front cover out. 

c.

 

Remove and discard any used filters. 

d.

 

Remove all packaging from the new filters and replace the filters in the 
order shown in the parts list section. 

e.

 

Replace the air purifier’s front cover. 

f.

 

After the filters have been replaced, plug the unit back into the power 
supply and turn it on. Press and hold the filter button for several seconds 
to reset the filter indicator. 

 

 

 

 

 

Summary of Contents for AP170W

Page 1: ...Because you re not like everyone else AIR PURIFIER AP170W AP400W OWNER S MANUAL ...

Page 2: ...e any questions or concerns regarding your product or if you would simply like to share an idea with us please feel free to contact us Our friendly and knowledgeable customer support team is here for you Call us today at 866 737 6390 or email support lumacomfort com For future reference we recommend you attach a copy of your sales receipt here and record the following information You will need thi...

Page 3: ...echnical Support 10 Product Specifications 10 Troubleshooting 10 Warranty 11 SAVE THESE INSTRUCTIONS Please carefully read this manual before attempting to use this air purifier For your own safety comply with all safety instructions and warnings contained in this owner s manual to prevent personal injury or property damage For best results we recommend operating your air purifier 24 hours a day 7...

Page 4: ... to fit into a matching receptacle Under no circumstances should the plug be altered in any way An improper connection can result in electric shock 10 If possible avoid using extension cords with this air purifier If an extension cord is absolutely necessary do not use more than one extension cord to operate more than one unit 11 Do not insert objects or allow fingers to enter into the air purifie...

Page 5: ...articles down to 0 1 micron Activated carbon pre filter captures large dust particles and reduces cooking tobacco and pet odors Advanced photo catalyst TiO2 filter and UV light reduce organic pollutants such as formaldehyde benzene and ammonia as well as kill bacteria and viruses Modern flat panel design fits in with any decor Whisper quiet fan draws air into the unit without disturbing your envir...

Page 6: ...HEPA filter VOC filter TiO2 mesh filter and UV refer to parts list Please note that the AP170W and AP400W models do not have the ionizer function Never operate the air purifier without the HEPA filter properly installed c Choose a suitable location for your air purifier For best results use the air purifier in an enclosed area with the doors and windows closed Also as a general rule the closer you...

Page 7: ...n to turn on the automatic timer The timer can be set from 1 to 7 hours The air purifier will turn off once the set time has been reached d Press the UV button to turn on the UV function and press it again to turn this function off UV light is used to destroy organic contaminants such as viruses mold and bacteria e The filter indicator light will turn on when the filters need to be replaced After ...

Page 8: ...ume will dramatically decrease at this time We recommend having a set of replacement filters on hand to ensure maximum performance a Before replacing any of the filters turn the air purifier off and unplug it from the power outlet b Open the air purifier s front grill by placing your hand on top of the air purifier s cover inserting your finger in the slot on the side of the unit and by pulling th...

Page 9: ... cleaning Use a soft cloth and a mild soap and warm water solution to clean the unit s exterior particularly the air intake grills and air outlet Do not use harsh cleaners gasoline paint thinner benzene etc as these substances can damage the air purifier Thoroughly dry all of the air purifier parts with a soft cloth before reconnecting the unit to the power supply If the air purifier will not be i...

Page 10: ...AP170W AP400W Product Dimensions 12 2 x 7 7 x 14 4 22 2 x 9 9 x 18 6 Product Weight 8 8 pounds 18 5 pounds Voltage 110V 120V 110V 120V Wattage 48W 100w Coverage Area 170 sq ft 500 sq ft Purification Methods HEPA filter carbon filter UV light TiO2 filter VOC filter Fan Speeds 3 Noise Level dB 53 25 52 4 50 5 57 2 51 6 48 6 Filter Life Indicator Yes Timer 1 7 hours Contaminants Removed Dust pollen b...

Page 11: ... tear of parts that are designed to be replaced such as filters or batteries Power failure and improper power supply such as low voltage defective wiring or inadequate fuses Use of force or damage caused by external influences Complete or partially dismantled appliances THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY INCLU...

Reviews: