EN
Manual XC200
3
Scope of delivery
Scope of delivery includes:
• 1 x Thermohygrometer XC200
• 1 x USB cable
• 4 x Alkaline LR6 AA, 1.5 V batteries
• 1 x Getting started guide
• 1 x Factory test certificate
Carefully read the operating manual before using the device
and keep it within reach!
• Do not use the device in atmospheres containing oil, sulphur,
chlorine or salt.
• Never use the device for measurements at live parts.
• Ensure that all connection cables are protected from
damages (e.g. from kinks or crushing).
• Protect the device from permanent direct sunlight.
• Observe the storage and operating conditions (see chapter
Intended use
Only use the thermohygrometer XC200 for indoor measurements
of temperature and humidity. Here, read and observe the
technical data.
To use the device for its intended use, only connect and use
accessories and spare parts which have been approved by
Lufft
®
.
Improper use
Do not use the device in potentially explosive atmospheres, or for
measurements in liquids. Lufft
®
accepts no liability for damages
resulting from improper use. In such a case, entitlements to a
warranty are forfeited. Any unauthorised modifications,
alterations or structural changes to the device are forbidden.
Personnel qualifications
People who use this device must:
• have read and understood the operating manual, especially
the Safety chapter.
For maintenance or repair work which requires the housing
to be opened, contact Lufft
®
customer service. Devices
which have been opened unlawfully are void of any warranty
and warranty claims.
Residual risks
Danger!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Danger!
The device is not a toy and does not belong in the hands
of children.
Danger!
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way.
Observe the personnel qualifications.
Caution!
To prevent damages to the device, do not expose it to
extreme temperatures, extreme humidity or moisture.
Caution!
Do not use abrasive cleaners or solvents to clean the
device.
Technical data
Parameter
Value
Temperature sensor
NTC
Measuring range
-20 to +50 °C
Tolerance
+/- 0.2 °C (0 to 40 °C), oth/-0.4 °C
Resolution
0.1 °C
Humidity sensor
Capacitive
Measuring range
0 to 100 % RH
Tolerance
+/- 2 % RH
Resolution
0.1 % RH
Measuring frequency
2x per second
Operating temperature
-20 °C to 50 °C
Storage temperature
-20 °C to 60 °C
Battery type
4x AA 1.5 VDC
Dimensions (LxWxH)
202 mm x 63 mm x 35 mm
Safety