Operating Manual
Compact Weather Station
78
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
18.6.5 Additional Measurement Commands
With the additional measurement commands
aM1! … aM6!
aMC1! … aMC6!
(M-Command, data transmission with CRC)
aC1! … aC6!
aCC1! … aCC6!
(C- Command, data transmission with CRC)
the complete data set of the compact weather station, as defined for the UMB protocol are
available in a SDI-12 environment as well.
The measurement values are ordered according to sensor types.
Equally to the base data sets max. 9 values can be requested with an additional M
command, while an additional C request allows for up to 20 values.
The buffer assignment as documented in the following paragraphs has consequently been
structured in a way that with each M command the buffers D0 and D1 are used. If the
respective sensor type has more values available the buffers D2 up to D4 will be occupied if
required.
M1 / C1
Temperature
M: 8 Values
C: 8 Values
M2 / C2
Humidity
M: 8 Values
C: 12 Values
M3 / C3
Air Pressure
M: 8 Values
C: 8 Values
M4 / C4
Wind
M: 9 Values
C: 12 Values
M5 / C5
Compass
M: 1 Values
C: 1 Values
M6 / C6:
Precipitation
M: 4 Values
C: 4 Values
M7 / C7
Global Radiation
M: 4 Values
C: 4 Values
If the sensor type requested with the measurement command is not available with the actual
variant of the compact weather station (WS200 ... WS600) the station will respond with
a0000<CR><LF>
bzw.
a00000<CR><LF>