background image

3. press                Measure — Recheck

1. Mount ROTALIGN

®

 & press

2. press                 Dimensions

To adjust the display contrast in the Start-up

Screen, press           to lighten and            to

darken.

To return to the Start-up Screen at any time,

press

0

1

MENU

CLR

Stationary

M.T.B.M.

Tip! Use these

at any time

LASER LIGHT
        DON'T STARE INTO BEAM
        CLASS II LASER PRODUCT

Note:
If application is for a horizontal machine and you
are on a horizontal machine as shown, proceed
to Step #2.

If you need to change the application,
select             or

Adjust thumbwheels on laser to center
of travel. 

Then

 switch on and adjust

beam onto center of receiver dustcap
by sliding laser up or down on risers.
Loosen bracket to adjust for side-to-
side.  (Avoid using the fine adjustment
thumbwheels just yet.) Remove cap

and center dot on target. 

Check the XY VIEW.

For Fine Adjustment:

  Up/down (Y-axis)—use top thumb-

wheel. Side-to-side (X-axis)—use side thumbwheel.

Rotate shaft one complete turn

(or at least 75

˚

).

START

STOP

Red LED Green LED Screen

1. Out of range

Steady

Off

'OFF'

2. Edge of range

Fast blink

Fast blink

'END'

3. Adjustment OK

Off

Slow blink

'OK'

Press

This is a good time to check soft foot. Of
course, soft foot can be checked any time.

5. press              Move

For Vertical or Horizontal Adjustment:

a) Press                then verify slow blinking green LED

on Receiver. *If not in range, press               and

adjust laser into inner circles.  Then press              .

Vertical

Left

Right

In

(Side view)

machine

machine

tolerance

Horizontal

Gap & Offset

Front & back

Out of

(Top view)

(symbols show

feet positions

tolerance

direction)

6. Recheck, go to step 3, press

If in range, press              and select              or             

.

START

V

ZOOM

H

ZOOM

STOP

b) Loosen bolts and shim or move machine.

c) Re-tighten bolts and press             

.

BOTH

Note, you can view the vertical and horizontal change

simultaneously in the Move mode by pressing             

.

For very large horizontal corrections adjust horizontally

before shimming.

XY

VIEW

MOVE

ESC

4. press               Results 

 (Coupling)

MOVE

1. Coupling diameter — Use 10"
2. Coupling center to receiver
3. Receiver     to front foot

4. Front foot to back foot

5. To use the tolerance feature, enter the RPM

in the following manner. Press Menu, select
Tolerances, select Table, enter RPM.

ENTER

ENTER

ENTER

ENTER

Note: On a new

alignment press

New Mach if there

are dimensions

here already!

For example press  9.75

  or press 9     

+

     3  /  4

ENTER

ENTER

Dimensions can be entered as decimals or fractions.

ON

OFF

Note: The optimum position to

set the Laser & Receiver in the

Move mode is 3 or 9 o'clock!

MENU

Laser

 is always mounted on the

Stationary Machine

                       (your 

L

eft)

Receiver 

is always mounted 

on

        

the

 

M

achine 

T

B

M

oved

                   

(your 

R

ight)

The Computer is

normally

 used

on the 9 o'clock
(left) side of the
machine.

Dimension reference mark
on top of the Receiver.

Note: If you use the Beam Deflector don't forget to deduct 2"!

CENTERED

*Version 2.0x firmware will Auto Start
the Move if Centered & within

±

 15  of

12:00, 3:00, 6:00 or 9:00 position.

˚

Reviews: