background image

 

 

‘Results’ Default

• Factory default is Coupling Results.

• Press 

 to toggle between 

 and 

 .

Press 

 to confirm selection.

Storing and Printing Data

Saves file

Opens file

Prints a report

Soft Foot

• Position shafts at either 90° or 270° (±4°).

• Adjust beam close to 

00

 if necessary.

Press 

. (Not necessary if "----" appears.)

• Press 

 then loosen the bolt, press 

to record value then tighten bolt.

• Press 

 or 

 to move to the next foot.

Follow this procedure for all remaining feet and
correct soft foot if greater than 0.002".

 

InfiniRange

®

• If

or

appear during rotation,

turn shafts back until numbers reappear.
(

InfiniRange then starts automatically.)

• Adjust beam close to 

00

 and press 

.

• Proceed with measurement.

Note: You may initiate 

InfiniRange manually at any

time by pressing  

 

 .

MASTERLIGN

®

Quick Reference

Version  1.1x

(Measurement Range Extension)

LUDECA, Inc.

1425 N.W. 88th Avenue, Miami, FL  33172
Phone: (305) 591-8935  •  Fax (305) 591-1537
[email protected] • www.ludeca.com

Visit us at: www.LaserAlignment.Net

V

oelzow & Company, Inc.

P.O. Box 158 • Wingate, NC  28174

704-233-9222  •  Fax  704-233-9211

E-mail: [email protected]

Web: www.LaserAlignment.net

Reviews: