‘Results’ Default
• Factory default is Coupling Results.
• Press
to toggle between
and
.
Press
to confirm selection.
Storing and Printing Data
Saves file
Opens file
Prints a report
Soft Foot
• Position shafts at either 90° or 270° (±4°).
• Adjust beam close to
00
if necessary.
Press
. (Not necessary if "----" appears.)
• Press
then loosen the bolt, press
to record value then tighten bolt.
• Press
or
to move to the next foot.
Follow this procedure for all remaining feet and
correct soft foot if greater than 0.002".
InfiniRange
®
• If
or
appear during rotation,
turn shafts back until numbers reappear.
(
InfiniRange then starts automatically.)
• Adjust beam close to
00
and press
.
• Proceed with measurement.
Note: You may initiate
InfiniRange manually at any
time by pressing
.
MASTERLIGN
®
Quick Reference
Version 1.1x
(Measurement Range Extension)
LUDECA, Inc.
1425 N.W. 88th Avenue, Miami, FL 33172
Phone: (305) 591-8935 • Fax (305) 591-1537
[email protected] • www.ludeca.com
Visit us at: www.LaserAlignment.Net
V
oelzow & Company, Inc.
P.O. Box 158 • Wingate, NC 28174
704-233-9222 • Fax 704-233-9211
E-mail: [email protected]
Web: www.LaserAlignment.net