4. Results
Coupling Results
• Press
until
appears. Press
or
or
to toggle through offset and
angular misalignment.
(+) Positive coupling offset
p
(-) Negative coupling offset
q
(+) Positive coupling gap
(-) Negative coupling gap
Repeat sections 3 and 4 to establish repeatability.
Foot Corrections
• Press
until
appears. Press
or
or
to toggle through vertical
shimming and horizontal move corrections.
Arrows show direction of move or shimming. Apply
correction to blinking foot.
600
5.0
9.0
10.0
15.0
1.8
3.0
900
3.0
6.0
7.0
10.0
1.2
2.0
1200
2.5
4.0
5.0
8.0
0.9
1.5
1800
2.0
3.0
3.0
5.0
0.6
1.0
3600
1.0
1.5
2.0
3.0
0.3
0.5
7200
0.5
1.0
1.0
2.0
0.2
0.3
2. Enter dimensions
•
1. Laser to prism
(Arrow point to hash mark "
φ
" on prism)
(Center-to-center of support posts)
•
2. Laser to center of coupling
(Center of flex planes)
•
3. Working diameter
10"
(Coupling diameter)
(Default value)
•
4. Laser to front foot
•
5. Front foot to back foot
1. Mount MASTERLIGN
®
and switch on
Stationary
Machine
MTBM
(Machine To
Be Moved)
All Speeds: Maximum Soft Foot Reading 2 mils.
Use OEM or in-house tolerances if available.
Tolerances for Shaft Alignment
Offset
(mils)
Excellent
Acceptable
RPM
Gap
(mils/10")
Excellent
Acceptable
Spacer Shaft
(mils/inch)
Excellent
Acceptable
3. Measure
• Adjust prism so that laser beam strikes center
of the prism cap cross hair.
• Remove cap.
• Adjust prism until coordinates are close
to
00
.
•
will appear on the screen.
• Rotate shafts at least 75°.
5. Move
• Rotate shafts until
45
°
appears (±4°)
• Adjust beam close to
00
if necessary.
• When
appears press
.
• Loosen bolts.
• Move machine horizontally into alignment.
• Retighten bolts.
• Repeat Sections 3 and 4.
Order No. 01-199-01
©1999 LUDECA, INC.
Masterlign and InfiniRange are registered trademarks of
Prueftechnik AG.
Resume: You can resume where you last left
off by pressing
.