RF:

RF:

RF:

RF:    
Frequency range 

 

 

 

87.5 to 108.00MHz 

Frequency stability   

 

 

Better than ±200Hz 

Output power 

 

 

 

0.1 – 800mW (nominal) 

Harmonic & spurious output 

 

< -63dBc typical 

AM Noise 

 

 

 

 

<0.5% @ ±40kHz deviation 

THD   

 

 

 

 

<0.15%@ ±75KHz deviation 

RF output connector 

 

 

‘N’ type (F) 

 
Monitoring:

Monitoring:

Monitoring:

Monitoring:    
RF 

 

 

 

 

 

BNC (F) -40dB 50 ohms 

MPX   

 

 

 

 

BNC (F) 1V P-P 10K ohms 

    
Audio Interface:

Audio Interface:

Audio Interface:

Audio Interface:    
Audio input level    

    

    

    

+8dBu for ±75KHz deviation 

Audio input impedance        

    

    

600 Ohms 

Audio input connectors 

 

 

XLR (F) 

 
Audio P

Audio P

Audio P

Audio Processing

rocessing

rocessing

rocessing::::    

Type 

Broadcast AGC, multiband 
levelling, clipping 

Stereo separation 

60dB 

19kHz filter 

Digital FIR 

Sampling 

 

 

 

 

56-bit, 48KHz 

Dynamic range 

 

 

 

98 dB 

THD (digital circuits)  

 

 

−90 dB 

Controls 

 

 

 

 

Factory fixed algorithm 

 
RDS:

RDS:

RDS:

RDS:    
Groups 

 

 

 

 

0A & 2A (others on request) 

 
Power Supply

Power Supply

Power Supply

Power Supply::::    
Input AC 

 

 

 

 

110V to 250V (50/60 Hz) 

Consumption (maximum RF output) 

9W (230V 50Hz) 

 
Mechanical:

Mechanical:

Mechanical:

Mechanical:    
Size (mm) 

 

 

 

 

1U 43 (H) x 482 (W) x 150 (D) 

Weight  

 

 

 

 

1kg 

Temperature  

 

 

 

0ºC to +42ºC 

Humidity  

 

 

 

 

95% (relative non-condensing) 

 
We reserve the right to alter specifications without notice. E&OE. 
 

Technical Specifications 

Summary of Contents for FMTX1

Page 1: ...ds cannot exceed safe limits The permitted permitted permitted permitted limits vary from country to country Expert advice limits vary from country to country Expert advice limits vary from country to country Expert advice limits vary from country to country Expert advice should be sought about the safe installation of this transmission should be sought about the safe installation of this transmis...

Page 2: ...nuous ous ous ous operation Schedule operation Schedule operation Schedule operation Schedule bi bi bi bi annual maintenance annual maintenance annual maintenance annual maintenance checks We strongly advise the use of a standby transmitter checks We strongly advise the use of a standby transmitter checks We strongly advise the use of a standby transmitter checks We strongly advise the use of a st...

Page 3: ...dalone a dedicated computer or data feed are not required Periodic content updates are easily performed using a Windows Laptop or PC plugged into a USB port located on the back panel At the heart of the FMTX1 is a high quality PLL modulator and the RF Power Amplifier uses the latest high gain Enhancement Mode MOSFET device achieving new levels of efficiency and reliability TTL remote monitoring an...

Page 4: ...cal shock along with telephone numbers for contacting the emergency services in the event of personal injury Ensure antenna system lightning strike protection is in place To reduce the risk of electrical shock do not remove the cover or any screws There are no user serviceable parts inside refer servicing to qualified personnel Do not expose this appliance to rain or moisture The transmitter shoul...

Page 5: ...liance may become warm under normal operating conditions Recycle according to WEEE regulations 1 RF MON RF MON RF MON RF MON BNC connector for monitoring of the RF output Output level will be the RF output level attenuated by approximately 40dB Not to be used for measurement of harmonics 2 MPX MON MPX MON MPX MON MPX MON BNC connector for monitoring of the input to the modulator baseband spectrum ...

Page 6: ...tion point M4 stud and bolt Connect a suitable rated test load to the RF OUPUT socket before connecting the unit to mains power IMPORTANT FAILURE TO DO SO MAY RESULT IN DAMAGE NOT COVERED BY WARRANTY Power up the unit and reduce the output power to the lowest level Using the front panel display and buttons set the desired transmission frequency The factory will have set the deviation RDS and pilot...

Page 7: ...ad and connect to the antenna Power up the unit and increase the RF Power using the rear panel RF ADJ control to the desired level not exceeding 1W The front panel display shows the forward power level reflected power level audio input levels ahead of any audio processing and transmission frequency Audio levels will be optimised by the Audio Processor however regular checks of audio levels enterin...

Page 8: ......

Page 9: ...WN DOWN buttons pressed whilst simultaneously powering up the FMTX1 This preference will be stored in non volatile memory and will therefore remain effective during power loss To re enable the RDS repeat the above procedure This preference will be stored in non volatile memory and will therefore remain effective during power loss ...

Page 10: ...this declaration refers to conforms to all applicable requirements of EU Directive 2014 53 EU and is CE marked accordingly Low Voltage Directive 2014 35 EU EN60215 1996 Safety Requirements for Radio Transmitting Equipment EMC Directive 2014 30 EU EN301489 1 ERM EMC for Radio Equipment Specific Conditions for FM Transmitters Part 11 Radio Equipment Directive 2014 53 EU EN302018 2 Transmitting Equip...

Page 11: ...ors XLR F Audio P Audio P Audio P Audio Processing rocessing rocessing rocessing Type Broadcast AGC multiband levelling clipping Stereo separation 60dB 19kHz filter Digital FIR Sampling 56 bit 48KHz Dynamic range 98 dB THD digital circuits 90 dB Controls Factory fixed algorithm RDS RDS RDS RDS Groups 0A 2A others on request Power Supply Power Supply Power Supply Power Supply Input AC 110V to 250V ...

Page 12: ...e information on the collection reuse and recycling systems please contact your local or regional waste administration IMPORTANT NO REPRESENTATIONS OR WARRANTIES EITHER EXPRESS OR IMPLIED OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE MADE WITH RESPECT TO THIS PRODUCT Do not misconstrue any information as our recommendation to use any product process or equipment in...

Page 13: ... of any kind with respect to this information Lucoro Broadcast specifically disclaims the implied warranty of merchantability and fitness for a particular purpose Lucoro Broadcast Clay Pit Lane Roecliffe York YO51 9FS Telephone 01423 313550 Telephone International 44 1423 313550 Enquiries sales lucorobroadcast com ...

Reviews: