16

15

3-1

3-2

L - 9

L ±15

325±20

325±20

1

2

(L + 40)

(4.5)

(19.5)

(4.5)

(19.5)

3-2

3-1

LFUS-T

**

WS

-L27-DF-O

Product specification

No

 

Item

 

Name Material etc.

1
2

4
5
6
7
8
9

10

Body

Lead wire

Connector

Connector

Diffuser

Aluminum

SUS

Input Voltage

DC24V

Mounting clip B

Aluminum mounting

rail C type

SUS hold clip C

Power supply cable

Connector cap

Joint cable

Joint Plate

SUS

SUS

+:Red 、

:Black

Unit Of Measure:mm

Spec・Rating may be subject to change without announcements.

3-2

3-2

3-1

8

10000±100

15

Ø15

Option parts

Power supply cable 10M for UQ FLEX

(CAD-V010M-FPNN-O)

Aluminium mounting rail C type950 for UQ FLEX H13

(

LFU-RL0950-AL-C

)

Option parts:

Option parts:

Joint cable 1M for UQ FLEX 

( CAD-1000-MPFP-O)

 Connector cap 

      is attached.

Accessories for rail & Option parts: 

SUS hold Clip C for UQ FLEX AL rail C

(LFU-PT-C)(5pcs/ 1bag)

Accessories for rail & Option parts: 

Joint plate for UQ FLEX AL rail C

(LFU-PT-D)(1pc/ 1bag)

Number of holes : 6

9

Ø14.5

16

12.8

M12

 35 

 200 

 200 

 35 

 150 

 150 

6

 

- Ø 4.8 through hole

 950 ±2 

15.5

22.6

2 - Ø 4.8 oblong hole

 2 

 70 

 140 

1.2

 2- 4.3 

7.3

16

35.4

28.1

2.5

4

(23.2)

(10)

(13.8)

(12.1)

5

6

7

Option parts :

Mounting clip B for UQ FLEX

(LFU-RC-B)

 (5pcs /1bag)

10

1000±15

Ø15

Released in May 2020

Red : +

Black : -

 Option parts

Connecting to the power supply

Option Parts

Power supply cable 10M 

for UQ FLEX

(CAD-V010M-FPNN-O)

+: Red

-: Black

DC output side 

(Connected to LED fixture)

power supply

Connection to the product

Product lead wires

+: Red

-: Black

with connector

AC input side

Cables used for connecting LED fixtures and Power supply must be a suitable type and gauge.

Cables should be joined with suitable terminal block or methods as appropriate 

to the installation and operating environment.

 Caution: When using a long cable with thin dimension, the resistance of cable will

 increase. Voltage drop and heat dispatching may occur and result in brightness decreasing.  
 Caution: When separating one cable to multiple circuits in the same gauge,

 the current loading focuses on the junction of the branch circuit and high 

 temperature will liberate on there.Please consider the loading of the power

 supply (quantity of LED fixture) and review the wiring system to avoid the

 above problem.

When connecting the dimmer driver with power supply, unpredicted 

noise might occur. It is a characteristic of electronic devices, 

not a malfunction of the LED fixture.Please choose an appropriate 

power supply and consider a place to install. Reducing the loading 

factor of LED fixture might improve the noise from the power supply 

while the noise for the LED fixtures might be improved by splitting 

the circuit of LED fixtures into multiple. 

Please do appropriate 

treatment on the connection 

of the cables depends on 

the installation situation.

When you adjust the length of the power supply cable, please be 

     careful not to damage the core wire.

unit of measure=mm

Product specification

unit of measure=mm

Luci UQ FLEX SAUNA

 

 

Luci UQ FLEX SAUNA

-

PWM, 0-10

Warm white 2700K(L27)

Item / Product Name

Lead wire & Cable type

Model No.

Power consumption
Input current

LED fixture length (L)

Environment
Operating temperature

Max. Length
Material (Body)

Attachments

Option parts

Dimmable
Light source color

Mounting clip B for UQ FLEX, Power supply cable 10M for UQ FLEX(Connector cap is attached), Joint cable1M for UQ FLEX 

 

Aluminum Mounting Rail C Type 950 for UQ FLEX H13, SUS hold clip C for UQ FLEX AL rail C, 

Joint plate for UQ FLEX AL rail C

Released in May 2020

Silicon

In & Outdoor, IP67   Humidity up to 95%RH

0

℃〜+

100

5m

2.6 W (Ta=25

℃)

5.1 W (Ta=25

℃)

1.3 W (Ta=25

℃)

(0.11 A  max)

(0.22 A  max)

(0.06 A  max)

1009mm

259mm

509mm

Both ends lead wire-Straight feed

LFUS-T0250WS-L27-DF-O

LFUS-T0500WS-L27-DF-O

LFUS-T1000WS-L27-DF-O

17.7

Summary of Contents for UQ FLEX SAUNA

Page 1: ...make sure to provide the air ventilation hole Always test before connecting the LED fixture to a switch or dimmer Do not use the product if the cover is damaged Risk of an accident and electrical shock Avoid spraying detergent directly on the LED fixture If this happens immediately rinse with water Do not use a brush or an abrasive to polish metal parts Risk of damage and corrosion Do not use in t...

Page 2: ...sistance of cable will increase Voltage drop and heat dispatching may occur and result in brightness decreasing Caution When separating one cable to multiple circuits in the same gauge the current loading focuses on the junction of the branch circuit and high temperature will liberate on there Please consider the loading of the power supply quantity of LED fixture and review the wiring system to a...

Page 3: ...ut according to the length of lighting fixture Aluminum rail mounting holes can also be made at the site by the installer Please cut properly with a cutting tool for aluminum Aluminum rail cut The Aluminium Mounting Rail C type 950 for UQ FLEX H13 LFU RL0950 AL C can be cut according to the length of lighting fixture Aluminum rail mounting holes can also be made at the site by the installer Please...

Page 4: ... about 50mm from the side cap to prevent lifting of the LED fixture 50mm recommend 50mm recommend Min R150mm OK NG Fix the mounting clip by 2pcs of screws supplied by installer pan head screw M4 recommended UQ FLEX SAUNA can be installed in curved surface as below picture The minimun bending radius is 150 mm Option parts Mounting Clip B for UQ FLEX LFU RC B Do not bend the LED fixture to side dire...

Reviews: