Working with Stinger Shelves and Modules
Viewing system components
Stinger®
Administration Guide
2-3
Viewing system components
You can use the
show
command and
slot-info
profile to display information about
the modules installed or configured in Stinger systems and the status of each module.
Using the
show
command
The
show
command lists the address of all modules installed in a Stinger system
including those installed in remote shelves, their required operating states and
current operating states, and the type of module installed.
Following is a sample output from a standalone Stinger FS, Stinger FS+, Stinger LS,
or Stinger RT,
admin>
show
Controller { first-control-module } ( PRIMARY ):
Reqd Oper Slot Type
{ shelf-1 slot-2 0 }
UP NONE stngr-48a-adsl-card
{ shelf-1 slot-3 0 }
UP UP al-dmtadsl-atm-card
{ shelf-1 slot-5 0 }
UP NONE dadsl-atm-24-card
{ shelf-1 slot-6 0 }
UP NONE dadsl-atm-24-card
{ shelf-1 slot-7 0 }
DOWN RESET glite-atm-48-card
{ shelf-1 slot-11 0 }
UP NONE stngr-48a-adsl-card
{ shelf-1 slot-14 0 }
DOWN RESET stngr-48b-adsl-card
{ shelf-1 trunk-module-1 0 } UP UP
ds3-atm-trunk-daughter-card
On an ADSL 36-port Stinger MRT, the
show
command displays the following output:
admin>
show
Shelf 1 ( standalone ):
Reqd
Oper
Slot Type
{ second-control-module }
UP
UP
( SECONDARY )
{ shelf-1 slot-1 0 }
UP
UP
mrt-36-adsl-card
{ shelf-1 trunk-module-1 0 } UP
UP
oc3-atm-trunk-daughter-card
{ shelf-1 trunk-module-2 0 } UP
UP
oc3-atm-trunk-daughter-card
On a unit with dual control modules, the
show
command identifies which control
module is primary. The command also lists the addresses of each slot with an installed
module.
On a hosted system, the
show
command displays information about all shelves with
an active control link to the host. For example, on a hosted Stinger MRT system, the
following command output shows that in addition to the host shelf (shelf ID 1),
shelves 3, 4, 5, and 6 have an active link to the host. For more information about
physical addressing on Stinger systems, see “Understanding physical addressing on
Stinger units” on page 2-1.
HOST>
show
Shelf 1 ( master ):
Reqd Oper Slot Type
{ shelf-1 slot-1 0 } UP UP mrt-36-adsl-card
{ shelf-1 trunk-module-1 0 } UP UP oc3-atm-trunk-daughter-card
{ shelf-1 trunk-module-2 0 } UP UP ds3-atm-trunk-daughter-card
{ shelf-3 slot-1 0 } UP UP mrt-36-adsl-card
{ shelf-3 first-control-mod+ UP UP mrt-cm
{ shelf-4 slot-1 0 } UP UP mrt-36-shdsl-card
{ shelf-4 first-control-mod+ UP UP mrt-cm
Summary of Contents for Stinger
Page 1: ...Stinger Administration Guide Part Number 7820 0712 008 For software version 9 7 0 August 2004 ...
Page 4: ......
Page 16: ......
Page 18: ......
Page 62: ......
Page 82: ......
Page 96: ......
Page 182: ......
Page 218: ......
Page 236: ......
Page 252: ......
Page 288: ......
Page 350: ......
Page 362: ......
Page 374: ......