5-4
Stinger®
Administration Guide
Monitoring Interfaces on LIMs and Trunk Modules
Using profiles to monitor LIM and trunk interfaces
vpi-vci-range = vpi-0-255-vci-32-8191
vc-switching-vpi = ""
vcc-vpi = [ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ]
f-bit-error-count = 512
p-bit-error-count = 24
cp-bit-error-count = 16
feb-error-count = 37
bpv-error-count = 22475
ezd-error-count = 45648
corrected-hec-error-count = 0
uncorrected-hec-error-count = 0
loss-of-signal = False
loss-of-frame = False
yellow-receive = False
ais-receive = False
For additional information about these parameters, see the
Stinger Reference
.
Monitoring LIM interfaces
The LIM status profiles shown in Table 5-2 include parameters and subprofiles that
report the following information for the line or port:
Physical address.
Status.
Redundancy settings.
Virtual path identifier (VPI) and virtual channel identifier (VCI) range.
VPI setting for virtual channel switching.
Error and statistic counters that are specific to that device.
Information specific to a particular device. For example, the status profiles for the
ADSL, SDSL, SHDSL, and SHDSL/HDSL2 LIMs include the following subprofiles:
–
physical-status
subprofile, which includes information about line and
modem status, firmware version, data rates, error counts, and operational
mode for the interface.
–
physical-statistics
subprofile, which includes information about signal
presence, modem integrity, operational statistics, and error statistics for the
interface.
The T1 and E1 modules enabled for IMA include the following subprofiles:
–
ima-link-status
subprofile, which provides information about the status of
an IMA link
–
ima-link-statistic
subprofile, which provides statistics for the IMA link.
–
ima-group-stat
subprofile, which monitors the performance of an IMA
group. This subprofile is created by the system automatically once the
imagroup
profile is properly configured and associated with a DS1-ATM
profile.
The following sample commands display the
al-dmt-stat
profile for port 5 on a 24-
port ADSL LIM installed in slot 2:
admin>
read al-dmt-stat {1 2 5}
AL-DMT-STAT/{ shelf-1 slot-2 5 } read
Summary of Contents for Stinger
Page 1: ...Stinger Administration Guide Part Number 7820 0712 008 For software version 9 7 0 August 2004 ...
Page 4: ......
Page 16: ......
Page 18: ......
Page 62: ......
Page 82: ......
Page 96: ......
Page 182: ......
Page 218: ......
Page 236: ......
Page 252: ......
Page 288: ......
Page 350: ......
Page 362: ......
Page 374: ......