Enclosure and Component Installation
Physical connections to the components
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
3
-33
Gigabit Ethernet port
This port supported on the IP2000 module. It provides a gigabit Ethernet connection
for end-user traffic, and can be used for administrative access. Stinger CR ATM
DSLAM units that are equipped with an IP2000 module have an enclosure door that
accommodates the optical fiber connection to the IP2000 (see Figure 1-3 on
page 1-5). The special curvilinear guided fiber cable, shipped with units that are
equipped with IP2000 modules, must be used. This connection is shown in
Figure 3-24.
Figure 3-24. Gigabit Ethernet connection to IP2000 module.
155Mbps optical port
This port is supported on the COP module. A 155Mbps optical connection to the COP requires
duplex small form factor (LC) fiber optic cable.
Caution:
Bind excess cable lengths in a figure-eight pattern. Do not wind excess cable
into circular coils.
Note:
Clean any fiber optic cables prior to connecting them.
To connect the optical jumper in the Stinger CR ATM DSLAM unit from the fiber tray to COP,
align the latch on the LC connector head of the jumper with the latching point on the side of
the LC connector in the COP and carefully insert the head of the jumper into the connector on
the COP, as shown in
COMPACT REMO
TE
COOLING UNIT
STATUS
INTERNAL
EXTERNAL
RED - FAULT
GREEN - ACTIVE
BLINKING GREEN - INITIALIZING
COMPACT REMO
TE POWER SUPPL
Y
V.CHECK
-48V
0V
STATUS
POWER INPUTS
-190V
+190V
ACT
LINK
Gig. E
Curvilinear guided
fiber cable