3-8
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
Enclosure and Component Installation
Mounting the enclosure on a pole
■
A 15/16 in. socket with a 2 in. extension (min.) and handle.
■
A 9/16 in. socket
■
A 10 inch (25cm) tongue and groove (channel lock) pliers
■
Safety screw driver for removal and installation of tribunal recessed head screws
(Part number 29-99-183-22, available from Southco Inc., or equivalent)
■
Phillips and slot screwdrivers
Follow all local safety practices and guidelines in performing this work to avoid injury
and the interruption of existing service.
Center-mounting the enclosure on a pole
To center-mount the rear of the enclosure to a pole, do not immediately remove the
shipping brackets or pallet from the base of the enclosure. The shipping brackets can
be used as handles to help lift and position the enclosure when mounting it. The
pallet also protects the cables below the chassis until it is mounted on the pole.
You may use the following procedure to center-mount (rear-mount) the enclosure to
a pole.
Note
These instructions assume that the pole is vertical. On poles that lean more
than 2°, additional precautions must be taken to be sure that the mounting bolts are
centered through the pole, and that the pole does not obstruct the enclosure cable
duct.
1
Use a 9/16 in. combination wrench or socket with a 6 in. extension and handle to
loosen the two nuts that secure the lag bolt tabs on the top and bottom pole
mounting brackets. The top bracket is shown in Figure 3-6. (These tabs must be
loose so that you can adjust them to the diameter of the pole when you install
the hardware. The tabs will be secured after the hardware is mounted on the
pole.)
Figure 3-6. Lag bolt tab adjustment
Loosen
Adjust
Lag bolt tab
Top pole mounting bracket