Configuring T1, E1, and ISDN PRI
10-7
Configuring ISDN PRI Settings
Setting the Channel Rate
Table 10-3
To set the channel rate to 56Kbps or 64Kbps for a channel group, use the
following command. Table 10-4 explains the channel rate options.
Command> set Line0 group Cgroup 56k|64k
Configuring ISDN PRI Settings
Use the following settings to configure ISDN PRI on the PortMaster 4.
Setting the ISDN PRI Switch
The switch type information is available from your ISDN PRI service provider. To set the
switch type for ISDN connections to the PortMaster ISDN PRI virtual ports, use the
following command—entered on one line. Table 10-5 explains the ISDN switch options.
Command> set isdn-switch ni-2|dms-100|4ess|att-5ess
|net5|vn2|vn3|1tr6|ntt|kdd|ts014
Cgroup
Group number from 1 to 63 that designates a port number
on each T1, E1, or ISDN PRI line, or none to unassign
channels.
Channel-list
Space-separated list of one or more channel numbers,
from 1 through 24 for T1, or 1 through 30 for E1. The
channel numbers do not have to be contiguous.
Table 10-4
Channel Rate Options
Option
Description
Line0
Line0 through Line3 (T1), Line0 through Line2 (E1).
Cgroup
Defined channel group from 1 to 63.
56k
56Kbps, typically used for D4 framing.
64k
64Kbps, used for framing types other than D4. This is the
default.
Table 10-5
ISDN Switch Options
ISDN Switch
Description
ni-2
National ISDN-2 (NI-2) compliant. This is the default.
dms-100
Northern Telecom DMS-100 Custom.
4ess
AT&T 4ESS.
att-5ess
AT&T 5ESS.
Table 10-2
Channel Group Options (Continued)
Option
Description
Summary of Contents for PortMaster 4
Page 12: ...Contents xii PortMaster Configuration Guide...
Page 24: ...Basic Configuration Steps 1 6 PortMaster 4 Configuration Guide...
Page 48: ...PortMaster Security Management 2 24 PortMaster 4 Configuration Guide...
Page 102: ...Testing Your Location Configuration 7 12 PortMaster 4 Configuration Guide...
Page 122: ...Configuring Ports for Modem Use 9 8 PortMaster 4 Configuration Guide...
Page 152: ...Performing Diagnostics 11 4 PortMaster 4 Configuration Guide...
Page 162: ...Frame Relay Subinterfaces 12 10 PortMaster 4 Configuration Guide...
Page 168: ...Troubleshooting a Leased Line Connection 13 6 PortMaster 4 Configuration Guide...
Page 182: ...Command Index Command Index 4 PortMaster 4 Configuration Guide...