FE-LAN CP failed
....................................................................................................................................................................................................................................
FE-LAN CP failed
Internal equipment failure of the specified 10/100 Fast Ethernet circuit
pack or communications problem between the 10/100 Fast Ethernet
pack and the system controller (SYSCTL) was detected.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Critical (CR)
AID (type)
Slot
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
FACTERM
Effect on
Service
SA
Alarm Entity
Type
EQPT
Description
FE-LAN CP failed
Likely Cause
A 10/100 Fast Ethernet circuit pack carrying
service failed - CR (SA).
A failure on a 10/100 Fast Ethernet circuit pack is
always CR (SA) as the Ethernet circuit packs are
unprotected.
Visible
indication
Lighted
CR/MJ
LED on SYSCTL faceplate and a
continuously lighted
FAULT
LED on the failed
circuit pack.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
3 - 3 2
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005