5
Release the cassette lever allowing the shutter door to close to its
initial position. Proceed to
............................................................................................................................................................
6
Wrap a Luminex cleaning cloth around the ferrule and rotate the
connector housing, cleaning the outside periphery of the ferrule.
Follow this by folding an unused portion of the cloth over the end of
the ferrule endface and then with light pressure from the thumb,
slightly drag the cloth from the center of the ferrule to the edge while
rotating the connector 360 degrees. If the Luminex cleaning cloth is
not available, a cleanroom optic wipe can be used. The Luminex
cleaning cloth is washable and can be used multiple times; optic
wipes are single use and disposable.
............................................................................................................................................................
7
Inspect the connector for cleanliness. If necessary, repeat the cleaning
process.
Reference:
“Procedure 6-15.3: Optical fiber and connector
E
N D
O F
S
T E P S
..............................................................................................................................................................................
Procedure 6-15.1: Clean optical fibers
Supporting procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
6 - 2 1 9