the latch to remove the pluggable transmission module from the
socket.
............................................................................................................................................................
7
Important! It is recommended that dust plugs be installed into
the optical ports on pluggable transmission modules to maintain
cleanliness until the optical fiber is connected.
On the pluggable transmission module you just removed, install dust
plugs into the optical ports to maintain cleanliness.
............................................................................................................................................................
8
Important! Do not remove the dust plug unless you are ready to
connect fibers or clean the pluggable transmission module.
Before installing the replacement pluggable transmission module, hold
the optical connector/latch-end of the pluggable transmission module
in your left hand with the gold fingers facing you. The pluggable
transmission module should be positioned in manner similar to
6-11, “Pluggable transmission module with dust plug” (6-206)
Figure 6-10 Latch type 4 (swivel latch opened and closed)
MA-DMX-424
Swivel Latch
Closed Position
(to the left)
Swivel Latch
Open Position
(to the right)
Figure 6-11 Pluggable transmission module with dust plug
MA-DMX-422
Procedure 6-14: Replace pluggable