Procedure 6-3.9: Log in serially and enable FTP and/or OSI on
the LAN port
....................................................................................................................................................................................................................................
Overview
Use this procedure to log in serially to a replacement SYSCTL and
enable OSI and/or FTP on LAN-1.
Procedure
Complete the following steps to log in to a SYSCTL serially.
............................................................................................................................................................
1
Using RS-232 cable with an RJ-45 connector on one end and a PC
serial connector on the other (typically DB9) for the
RS232
port,
connect the
COM1
or
COM2
port of your PC to the
RS232
serial port
on the faceplate of the SYSCTL circuit pack.
Important! DO NOT establish a WaveStar
®
CIT session.
............................................................................................................................................................
2
Do you know the TID and the user ID and password for the
replacement SYSCTL?
If...
Then...
Yes
Continue with
to log in and enable
FTP (using the TERM window) or Proceed to
to enable OSI on LAN-1.
No
Continue with
to determine the TID.
............................................................................................................................................................
3
Double-click on the DMX Family Software folder on your Desktop.
Result:
The DMX Family Software folder contains the
short-cut icon for the Metropolis
®
DMXplore software
release to be installed. Your software release may be
different.
Supporting procedures
....................................................................................................................................................................................................................................
6 - 1 3 4
Lucent Technologies
365-372-333 R2.1