Result:
The CIT OSI Neighbor(s) is automatically detected.
The resulting NE icon also provides a visual confirmation
of the NE’s TID. In all cases, the default user ID and
password for Metropolis
®
DMXplore will be used to log in
to the NE.
If you were previously logged in to the NE and/or you do not
see your NE, from the Network View, select
View
→
Refresh
OSI View
.
If your SYSCTL was not factory-fresh and you do not see your NE in
the Network View, it is possible that OSI was previously disabled on
LAN-1. Proceed to
“Procedure 6-3.9: Log in serially and enable FTP
and/or OSI on the LAN port” (6-134)
to log in and enable OSI.
Figure 6-8 CIT OSI neighbor
Procedure 6-3: Replace a SYSCTL
(VLNC1) circuit pack
Supporting procedures
....................................................................................................................................................................................................................................
6 - 4 0
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005