3
From the System View, click the
Alarm List
button and click
Refresh
.
............................................................................................................................................................
4
Is the
inc. OCN RFI-L
condition/alarm still present?
If...
Then...
Yes
Continue with
No
STOP! End of Procedure.
............................................................................................................................................................
5
Refer to the Probable Cause column in the alarm list, determine the
OC-N line affected by the
inc. OCN RFI-L
alarm, and note the
corresponding AID.
............................................................................................................................................................
6
Visually check the local transmit fiber connections between the circuit
pack faceplate and the LGX panel or equivalent connection point for
faulty connections or damage.
If faulty connections or
damage...
Then...
was found,
Follow local procedures to
repair/replace as necessary. Then
continue with
was not found,
Proceed to
............................................................................................................................................................
7
From the System View, click the
Alarm List
button and click
Refresh
.
............................................................................................................................................................
8
Is the
inc. OCN RFI-L
condition/alarm still present?
If...
Then...
Yes
Continue with
Procedure 5-30: Clear
″
inc. OCN RFI-L
″
condition/alarm
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 9 3