Procedure 5-30: Clear
″
inc. OCN RFI-L
″
condition/alarm
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear an
inc. OCN RFI-L
condition/alarm
indicated by a lighted Critical/Major (
CR/MJ
) or Minor (
MN/ABN
)
LED on the SYSCTL faceplate and reported as major, minor, or Not
Alarmed in the WaveStar
®
CIT Alarm List.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
and
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear an
inc. OCN RFI-L
condition/alarm.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the
Alarm List
button
and locate the
inc. OCN RFI-L
condition/alarm in the resulting alarm
list.
............................................................................................................................................................
2
Important! The
inc. OCN RFI-L
condition/alarm indicates that
the far-end network element has detected a bad OC-N signal
from this network element. The
inc. OCN RFI-L
condition/alarm
is normally cleared by addressing other alarms/conditions.
Are there other conditions/alarms in the alarm list?
If...
Then...
Yes
Proceed to the appropriate
procedure(s) to clear the alarms in
order of severity, CR, (SA), MJ (SA),
MJ (NSA), MN (NSA), and then Not
Alarmed. Then continue with
No
Continue with
Trouble clearing procedures
....................................................................................................................................................................................................................................
5 - 9 2
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005