10
Is the alarm an
inc. DS3 LOF
?
If...
Then...
Yes
Determine and record the signal format
of the far-end port connected to the
alarmed port on the Metropolis
®
DMXplore and then continue with
No
Proceed to
............................................................................................................................................................
11
From the Metropolis
®
DMXplore System View, select
View
→
Equipment
, expand the group (GRP), highlight the alarmed port, and
click
Select
.
............................................................................................................................................................
12
Compare the signal format of the Metropolis
®
DMXplore port against
the information determined about the far-end port. If there are
inconsistencies, determine the correct provisioning and correct
according to local procedures.
If the Metropolis
®
DMXplore port is provisioned incorrectly, from the
System View, select
Configuration
→
Equipment
, expand the group
(GRP), highlight the alarmed port, and click
Select
. Provision the
Signal Format appropriately, click
Apply
, and then click
Close
.
............................................................................................................................................................
13
From the System View, click the
Alarm List
button and click
Refresh
.
............................................................................................................................................................
14
Is the
inc. DS3
alarm still present?
If...
Then...
Yes
Continue with
No
Proceed to
Procedure 5-25: Clear
″
inc. DS3
″
conditions/alarms
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 7 7